<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Projects &#8211; Kelly Flanagan</title>
	<atom:link href="/category/hardware-software/feed/index.xml" rel="self" type="application/rss+xml" />
	<link>/</link>
	<description>Learn, share, and inspire!</description>
	<lastBuildDate>Tue, 09 Jun 2026 23:13:17 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>
	<item>
		<title>Refining My Blog Pipeline with Claude</title>
		<link>/refining-my-blog-pipeline-with-claude/</link>
		
		<dc:creator><![CDATA[flanagan]]></dc:creator>
		<pubDate>Tue, 09 Jun 2026 23:13:17 +0000</pubDate>
				<category><![CDATA[Professional]]></category>
		<category><![CDATA[Programming]]></category>
		<category><![CDATA[Projects]]></category>
		<category><![CDATA[AI]]></category>
		<category><![CDATA[AWS]]></category>
		<category><![CDATA[Claude]]></category>
		<category><![CDATA[Static]]></category>
		<category><![CDATA[Static Website]]></category>
		<category><![CDATA[Website Hosting]]></category>
		<guid isPermaLink="false">/?p=4154</guid>

					<description><![CDATA[In a previous post, I described how I migrated flanagan.io from a hosted WordPress site to a static site served from AWS S3 and CloudFront, managed by a Makefile. The pipeline worked, but after living with it for a while I noticed some things that bothered me: I spent about an hour co-working through the&#8230;&#160;]]></description>
										<content:encoded><![CDATA[<div class="wp-block-image">
<figure class="alignright size-medium"><img fetchpriority="high" decoding="async" width="300" height="200" src="/wp-content/uploads/2025/10/ChatGPT-Image-Oct-22-2025-07_29_13-PM-300x200.png" alt="" class="wp-image-3338" srcset="/wp-content/uploads/2025/10/ChatGPT-Image-Oct-22-2025-07_29_13-PM-300x200.png 300w, /wp-content/uploads/2025/10/ChatGPT-Image-Oct-22-2025-07_29_13-PM-1024x683.png 1024w, /wp-content/uploads/2025/10/ChatGPT-Image-Oct-22-2025-07_29_13-PM-768x512.png 768w, /wp-content/uploads/2025/10/ChatGPT-Image-Oct-22-2025-07_29_13-PM-930x620.png 930w, /wp-content/uploads/2025/10/ChatGPT-Image-Oct-22-2025-07_29_13-PM.png 1536w" sizes="(max-width: 300px) 100vw, 300px" /></figure>
</div>


<p class="wp-block-paragraph">In a <a href="https://flanagan.io/wordpress-to-static-simplifying-my-blog/">previous post</a>, I described how I migrated flanagan.io from a hosted WordPress site to a static site served from AWS S3 and CloudFront, managed by a Makefile. The pipeline worked, but after living with it for a while I noticed some things that bothered me:</p>



<ul class="wp-block-list">
<li>Directory and makefile target naming that didn&#8217;t quite reflect reality</li>



<li>A not so subtle bug in the GitHub sync step</li>



<li>No way to recover if a deploy went sideways</li>
</ul>



<p class="wp-block-paragraph">I spent about an hour co-working through the Makefile with Claude, and the result is a noticeably cleaner, more robust pipeline.</p>



<h3 class="wp-block-heading">What Was Wrong with the Naming</h3>



<p class="wp-block-paragraph">The original Makefile used three directories: curr_public_static, prev_public_static, and diff_public_static. The intent was that curr held the new export you were about to deploy and prev held the last-deployed baseline used for comparison. The problem is that &#8220;current&#8221; implies what&#8217;s live right now—which is the opposite of how the directories were actually used. Anyone reading the Makefile cold (including future me) would have to think backwards to understand it.</p>



<p class="wp-block-paragraph">The fix was to rename them so the names match the mental model: next_public_static for the incoming export, curr_public_static for what&#8217;s actually live on S3, and diff_public_static for changed items. After a deploy, next is promoted to curr as the new baseline. The direction of everything in the Makefile now reads naturally.</p>



<pre class="wp-block-preformatted">CURR_DIR := $(HOME)/Local Sites/flanaganio/app/curr_public_static
NEXT_DIR := $(HOME)/Local Sites/flanaganio/app/next_public_static
DIFF_DIR := $(HOME)/Local Sites/flanaganio/app/diff_public_static
PREV_DIR := $(HOME)/Local Sites/flanaganio/app/prev_public_static</pre>



<p class="wp-block-paragraph">I also replaced the hardcoded /Users/kelly.flanagan/ path prefix with $(HOME), so the Makefile isn&#8217;t tied to a specific username. This became an issue when I changed machines and forced to adopt this new user name.</p>



<h3 class="wp-block-heading">A Bug the Renaming Exposed</h3>



<p class="wp-block-paragraph">Once the names were fixed, a bug in github_copy became obvious. The original code set LOCAL_DIR := $(PREV_DIR) and synced from there to GitHub—meaning every deploy pushed the <em>old</em> version of the site to GitHub, not the new one. It had always been wrong; the confusing names just obscured it. With clear names, syncing curr (old) instead of next (new) to GitHub was immediately visible. The fix was one line.</p>



<h3 class="wp-block-heading">Pre-flight Check</h3>



<p class="wp-block-paragraph">If Simply Static fails silently and exports an empty or near-empty directory, the old pipeline would happily sync nothing to S3 and wipe the live site. A check_next target now runs first and aborts if next_public_static contains fewer than 100 files.</p>



<pre class="wp-block-preformatted">check_next:
    @file_count=$$(find "$(NEXT_DIR)" -type f | wc -l | tr -d ' '); \
    if [ "$$file_count" -lt $(MIN_FILE_COUNT) ]; then \
        echo "ERROR: $(NEXT_DIR) contains only $$file_count files (minimum: $(MIN_FILE_COUNT)). Aborting."; \
        exit 1; \
    fi
    @echo "Pre-flight check passed: $$(find "$(NEXT_DIR)" -type f | wc -l | tr -d ' ') files in next_public_static."</pre>



<h3 class="wp-block-heading">Smarter CloudFront Invalidation</h3>



<p class="wp-block-paragraph">The original pipeline invalidated all paths on every deploy—which works, but clears the entire cache even when only one post changed. Since diff_dir already knows exactly which files changed, it made sense to invalidate only those paths. The updated target does that, with a fallback to all paths when more than 50 files changed.</p>



<pre class="wp-block-preformatted">invalidate_cloudfront_caches:
    @echo "Creating CloudFront invalidation."
    @file_count=$$(find "$(DIFF_DIR)" -type f | wc -l | tr -d ' '); \
    if [ "$$file_count" -gt 50 ]; then \
        echo "$$file_count files changed — invalidating /*"; \
        aws cloudfront create-invalidation --distribution-id "$(CF_DISTRIBUTION_ID)" --paths "/*" &gt; /dev/null; \
    else \
        paths=$$(find "$(DIFF_DIR)" -type f | sed "s|$(DIFF_DIR)||g" | tr '\n' ' '); \
        echo "Invalidating $$file_count paths."; \
        aws cloudfront create-invalidation --distribution-id "$(CF_DISTRIBUTION_ID)" --paths $$paths &gt; /dev/null; \
    fi
    @echo "Invalidation request submitted."</pre>



<h3 class="wp-block-heading">Rollback</h3>



<p class="wp-block-paragraph">The original pipeline had no recovery path. If a deploy produced a broken site, the only option was to re-export, fix whatever was wrong, and deploy again—hoping the fix worked. The updated pipeline adds a fourth directory, prev_public_static, which holds a snapshot of curr taken just before promotion. If something goes wrong after a deploy, make rollback restores the previous version to S3, invalidates CloudFront, and resets curr to match.</p>



<pre class="wp-block-preformatted">backup_curr:
    @echo "Backing up $(CURR_DIR) to $(PREV_DIR)"
    @mkdir -p "$(PREV_DIR)"
    @rsync -a --delete "$(CURR_DIR)/" "$(PREV_DIR)/"
    @echo "Backup complete."

rollback:
    @if [ ! -d "$(PREV_DIR)" ] || [ -z "$$(ls -A "$(PREV_DIR)")" ]; then \
        echo "ERROR: No previous version found at $(PREV_DIR). Cannot rollback."; \
        exit 1; \
    fi
    @echo "Rolling back to previous version..."
    @aws s3 sync "$(PREV_DIR)/" "$(S3_BUCKET)" --delete --quiet
    @echo "S3 restore complete."
    @aws cloudfront create-invalidation --distribution-id "$(CF_DISTRIBUTION_ID)" --paths "/*" &gt; /dev/null
    @echo "CloudFront invalidation submitted."
    @rsync -a --delete "$(PREV_DIR)/" "$(CURR_DIR)/"
    @echo "Rollback complete. Note: next_public_static still contains the failed deploy — re-export before deploying again."
    @echo "$$(date '+%Y-%m-%d %H:%M:%S') Rollback complete" &gt;&gt; "$(LOG_FILE)"</pre>



<p class="wp-block-paragraph">This is single-level rollback—one deploy back. Good enough for a personal blog where I&#8217;m the only one making changes.</p>



<h3 class="wp-block-heading">Other Small Things</h3>



<p class="wp-block-paragraph">A few other improvements accumulated along the way. The &#8211;exact-timestamps flag on aws s3 sync was replaced with the default ETag-based comparison, which is more reliable when file timestamps get reset after a fresh export. Error handling within recipe steps was tightened—critical command sequences now use &amp;&amp; instead of ;, so a failure stops the chain rather than silently continuing. The CloudFront invalidation no longer swallows stderr, so actual AWS errors surface instead of being hidden behind a cheerful &#8220;Invalidation request submitted.&#8221; And a deploy.log file now records a timestamped line on each successful deploy and rollback, so there&#8217;s a simple record of when things ran.</p>



<p class="wp-block-paragraph">The full deploy chain now looks like this:</p>



<pre class="wp-block-preformatted">deploy: clean check_next fix_feed diff_dir s3_upload invalidate_cloudfront_caches github_copy backup_curr next_to_curr
    @echo "Deployment complete."
    @echo "$$(date '+%Y-%m-%d %H:%M:%S') Deployment complete" &gt;&gt; "$(LOG_FILE)"</pre>



<h3 class="wp-block-heading">Working with Claude</h3>



<p class="wp-block-paragraph">I&#8217;ve used AI tools before to generate boilerplate or look up syntax, but this session felt different. Rather than asking Claude to write the Makefile from scratch, I described what I had and talked through what bothered me about it. Claude spotted the naming inversion and the GitHub bug independently—I hadn&#8217;t framed either as a bug, just noticed the names felt off. From there it was a back-and-forth: Claude would propose a change, I&#8217;d push back or ask why, and we&#8217;d refine it together. The rollback design in particular went through a few iterations before landing on something I was happy with.</p>



<p class="wp-block-paragraph">The end result is a Makefile I&#8217;d actually feel comfortable handing to someone else to use, because the next time I look at it, I will be a different person having no idea how it works. Claude will explain ti to me then as well.</p>



<h3 class="wp-block-heading">Makefile</h3>



<pre class="wp-block-preformatted">.PHONY: deploy check_next diff_dir s3_upload invalidate_cloudfront_caches github_copy backup_curr next_to_curr rollback fix_feed clean help

# Directory paths
CURR_DIR := $(HOME)/Local Sites/flanaganio/app/curr_public_static
NEXT_DIR := $(HOME)/Local Sites/flanaganio/app/next_public_static
DIFF_DIR := $(HOME)/Local Sites/flanaganio/app/diff_public_static
PREV_DIR := $(HOME)/Local Sites/flanaganio/app/prev_public_static
LOG_FILE := $(HOME)/Local Sites/flanaganio/app/deploy.log
S3_BUCKET := s3://flanaganio-static/
CF_DISTRIBUTION_ID := E1JU16LZYIE94I
GITHUB_DIR := $(HOME)/Local Sites/flanaganio/app/flanagan.io

# Rsync options: compare next against curr to find only changed files
RSYNC_OPTS := -ac --delete --compare-dest="$(CURR_DIR)/"

# Minimum file count in next_public_static — abort if below this threshold
MIN_FILE_COUNT := 100

# Full deployment: clean, pre-flight, fix feed, diff, S3 upload, CloudFront, GitHub, backup curr, promote next→curr
deploy: clean check_next fix_feed diff_dir s3_upload invalidate_cloudfront_caches github_copy backup_curr next_to_curr
	@echo "Deployment complete."
	@echo "$$(date '+%Y-%m-%d %H:%M:%S') Deployment complete" &gt;&gt; "$(LOG_FILE)"

# Abort if next_public_static looks empty or incomplete
check_next:
	@file_count=$$(find "$(NEXT_DIR)" -type f | wc -l | tr -d ' '); \
	if [ "$$file_count" -lt $(MIN_FILE_COUNT) ]; then \
		echo "ERROR: $(NEXT_DIR) contains only $$file_count files (minimum: $(MIN_FILE_COUNT)). Aborting to prevent a broken deploy."; \
		exit 1; \
	fi
	@echo "Pre-flight check passed: $$(find "$(NEXT_DIR)" -type f | wc -l | tr -d ' ') files in next_public_static."

# Compare $(NEXT_DIR) against $(CURR_DIR) and output changed files to $(DIFF_DIR)
diff_dir:
	@echo "Comparing $(NEXT_DIR) against $(CURR_DIR)"
	# Raise open-file limit to prevent rsync failures on large site exports
	@ulimit -n 65536 &amp;&amp; \
	rm -rf "$(DIFF_DIR)" &amp;&amp; \
	mkdir -p "$(DIFF_DIR)" &amp;&amp; \
	rsync $(RSYNC_OPTS) "$(NEXT_DIR)/" "$(DIFF_DIR)/"
	@file_count=$$(find "$(DIFF_DIR)" -type f | wc -l | tr -d ' '); \
	total_size=$$(du -sh "$(DIFF_DIR)" | awk '{print $$1}'); \
	echo "Comparison complete."; \
	echo "Files changed: $$file_count ($$total_size)"

# Upload diff directory to S3
s3_upload:
	@echo "Uploading $(DIFF_DIR) to $(S3_BUCKET)"
	@aws s3 sync "$(DIFF_DIR)/" "$(S3_BUCKET)" --quiet
	@echo "Upload complete."

# Invalidate only the changed CloudFront paths; fall back to /* if count exceeds 50
invalidate_cloudfront_caches:
	@echo "Creating CloudFront invalidation."
	@file_count=$$(find "$(DIFF_DIR)" -type f | wc -l | tr -d ' '); \
	if [ "$$file_count" -gt 50 ]; then \
		echo "$$file_count files changed — invalidating /*"; \
		aws cloudfront create-invalidation --distribution-id "$(CF_DISTRIBUTION_ID)" --paths "/*" &gt; /dev/null; \
	else \
		paths=$$(find "$(DIFF_DIR)" -type f | sed "s|$(DIFF_DIR)||g" | tr '\n' ' '); \
		echo "Invalidating $$file_count paths."; \
		aws cloudfront create-invalidation --distribution-id "$(CF_DISTRIBUTION_ID)" --paths $$paths &gt; /dev/null; \
	fi
	@echo "Invalidation request submitted."

# Sync next_public_static to GitHub and push
github_copy:
	@echo "Syncing $(NEXT_DIR) to GitHub."
	@rsync -a --delete --exclude ".git/" --exclude ".DS_Store" --quiet "$(NEXT_DIR)/" "$(GITHUB_DIR)/"
	@cd "$(GITHUB_DIR)" &amp;&amp; \
	if [ -n "$$(git status --porcelain)" ]; then \
		UPDATED_COUNT=$$(git status --porcelain | wc -l | tr -d ' '); \
		git add . &gt;/dev/null &amp;&amp; \
		git commit -m "Update static site $$(date '+%Y-%m-%d %H:%M:%S')" &amp;&amp; \
		git push --quiet origin main; \
		TOTAL_SIZE=$$(du -sh "$(GITHUB_DIR)" | awk '{print $$1}'); \
		echo "Updated $$UPDATED_COUNT files to GitHub (current size $$TOTAL_SIZE)."; \
	else \
		echo "No changes to commit."; \
	fi
	@echo "GitHub sync complete."

# Promote next_public_static → curr_public_static for the next deployment's baseline
next_to_curr:
	@echo "Promoting $(NEXT_DIR) to $(CURR_DIR)"
	@rsync -a --delete "$(NEXT_DIR)/" "$(CURR_DIR)/"
	@echo "Promotion complete."

# Save curr_public_static → prev_public_static before promoting next (enables rollback)
backup_curr:
	@echo "Backing up $(CURR_DIR) to $(PREV_DIR)"
	@mkdir -p "$(PREV_DIR)"
	@rsync -a --delete "$(CURR_DIR)/" "$(PREV_DIR)/"
	@echo "Backup complete."

# Restore prev_public_static to S3 and reset curr (single-level rollback)
rollback:
	@if [ ! -d "$(PREV_DIR)" ] || [ -z "$$(ls -A "$(PREV_DIR)")" ]; then \
		echo "ERROR: No previous version found at $(PREV_DIR). Cannot rollback."; \
		exit 1; \
	fi
	@echo "Rolling back to previous version..."
	@aws s3 sync "$(PREV_DIR)/" "$(S3_BUCKET)" --delete --quiet
	@echo "S3 restore complete."
	@aws cloudfront create-invalidation --distribution-id "$(CF_DISTRIBUTION_ID)" --paths "/*" &gt; /dev/null
	@echo "CloudFront invalidation submitted."
	@rsync -a --delete "$(PREV_DIR)/" "$(CURR_DIR)/"
	@echo "Rollback complete. Note: next_public_static still contains the failed deploy — re-export before deploying again."
	@echo "$$(date '+%Y-%m-%d %H:%M:%S') Rollback complete" &gt;&gt; "$(LOG_FILE)"

# Fix relative URLs in RSS feed before deployment
fix_feed:
	@echo "Converting relative URLs to absolute in RSS feed."
	@if [ -f "$(NEXT_DIR)/feed/index.xml" ]; then \
		sed -i '' -E \
			's|/wp-content/|https://flanagan.io/wp-content/|g; \
			 s|href="/|href="https://flanagan.io/|g; \
			 s|src="/|src="https://flanagan.io/|g; \
			 s|srcset="/|srcset="https://flanagan.io/|g; \
			 s|&lt;link&gt;/|&lt;link&gt;https://flanagan.io/|g' \
			"$(NEXT_DIR)/feed/index.xml"; \
		echo "RSS feed URLs updated successfully."; \
	else \
		echo "RSS feed not found at $(NEXT_DIR)/feed/index.xml"; \
	fi

# Clean diff directory
clean:
	@echo "Cleaning up $(DIFF_DIR)"
	@rm -rf "$(DIFF_DIR)"
	@echo "Done."

# List available targets
help:
	@echo ""
	@echo "Available targets:"
	@echo "  deploy                        Full deployment: clean, pre-flight check, fix feed, diff, S3 upload, CloudFront invalidation, GitHub push, backup curr, promote next→curr"
	@echo "  rollback                      Restore prev_public_static to S3 and reset curr (single-level)"
	@echo "  check_next                    Abort if next_public_static has fewer than $(MIN_FILE_COUNT) files"
	@echo "  fix_feed                      Rewrite relative URLs to absolute in the RSS feed"
	@echo "  diff_dir                      Compute changed files between next and curr"
	@echo "  s3_upload                     Upload changed files to S3"
	@echo "  invalidate_cloudfront_caches  Invalidate changed CloudFront paths (or /* if &gt;50 files changed)"
	@echo "  github_copy                   Sync next to the GitHub repo and push"
	@echo "  backup_curr                   Save curr_public_static to prev_public_static"
	@echo "  next_to_curr                  Promote next_public_static to curr_public_static"
	@echo "  clean                         Remove the diff directory"
	@echo ""
</pre>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>WordPress to Static: Simplifying My Blog</title>
		<link>/wordpress-to-static-simplifying-my-blog/</link>
		
		<dc:creator><![CDATA[flanagan]]></dc:creator>
		<pubDate>Thu, 23 Oct 2025 01:15:03 +0000</pubDate>
				<category><![CDATA[Professional]]></category>
		<category><![CDATA[Programming]]></category>
		<category><![CDATA[Projects]]></category>
		<category><![CDATA[API]]></category>
		<category><![CDATA[AWS]]></category>
		<category><![CDATA[Static]]></category>
		<category><![CDATA[Static Website]]></category>
		<category><![CDATA[Website Hosting]]></category>
		<guid isPermaLink="false">/?p=3280</guid>

					<description><![CDATA[Introduction On July 2, 2015, I published my first blog post—an article about the importance of owning your own domain and publishing your work on a platform you control. At the time, my site ran on WordPress hosted by Reclaim Hosting, who proved to be an excellent partner. However, as my career wound down, I&#8230;&#160;]]></description>
										<content:encoded><![CDATA[
<h3 class="wp-block-heading"><strong>Introduction</strong></h3>



<p class="wp-block-paragraph">On July 2, 2015, I published <a href="https://flanagan.io/domain-of-ones-own-byu/">my first blog post</a>—an article about the importance of owning your own domain and publishing your work on a platform you control. At the time, my site ran on <a href="https://wordpress.com/">WordPress</a> hosted by <a href="https://www.reclaimhosting.com/">Reclaim Hosting</a>, who proved to be an excellent partner.</p>



<p class="wp-block-paragraph">However, as my career wound down, I realized that WordPress offered far more features, with associated complexity,  than I needed for the kind of content I post. What I really wanted was a simple, low-maintenance, and inexpensive static site. This post describes my journey toward that goal.</p>



<h3 class="wp-block-heading"><strong>Desired Workflow</strong></h3>


<div class="wp-block-image">
<figure class="alignright size-medium"><img decoding="async" width="300" height="200" src="/wp-content/uploads/2025/10/Workflow-300x200.jpg" alt="" class="wp-image-3321" srcset="/wp-content/uploads/2025/10/Workflow-300x200.jpg 300w, /wp-content/uploads/2025/10/Workflow-1024x683.jpg 1024w, /wp-content/uploads/2025/10/Workflow-768x512.jpg 768w, /wp-content/uploads/2025/10/Workflow-930x620.jpg 930w, /wp-content/uploads/2025/10/Workflow.jpg 1536w" sizes="(max-width: 300px) 100vw, 300px" /></figure>
</div>


<p class="wp-block-paragraph">I’ve always enjoyed using WordPress to create content and manage associated media files. With that in mind, I decided to continue using WordPress locally on my own machine as a comfortable writing and organization environment.</p>



<p class="wp-block-paragraph">My goal was to generate a visually and functionally identical static site—built entirely with HTML, CSS, and JavaScript—that mirrors my local WordPress site. Once generated, the static files could be uploaded to a hosting service, making my content available to others with minimal cost and complexity.</p>



<h3 class="wp-block-heading"><strong>Local WordPress Site</strong></h3>



<p class="wp-block-paragraph">The first step in moving my blog from a hosted WordPress instance to a local setup was to install <a href="https://localwp.com/">LocalWP</a>, an OS X-compatible WordPress development environment. Once installed, I configured LocalWP to host a WordPress site that would eventually become flanagan.io.</p>



<p class="wp-block-paragraph">When the site is “started” within LocalWP, it becomes available at flanaganio.local and administered at  flanaganio.local/wp-login.php.  LocalWP automatically handles everything behind the scenes—creating the necessary database(s), updating the /etc/hosts file, and installing WordPress itself.</p>



<p class="wp-block-paragraph">After setting up the local environment, I backed up my hosted WordPress site and imported the backup into WordPress running on LocalWP. At this point, flanaganio.local functioned identically to my hosted site at kelly.flanagan.io  It seemed like the next step would simply be to install the <a href="https://wordpress.org/plugins/simply-static/">Simply Static</a> plugin, run it, and host the resulting files somewhere. Not quite!</p>



<h3 class="wp-block-heading"><strong>Lessons Learned and Adjustments</strong></h3>



<p class="wp-block-paragraph">My first attempts at generating a static version of the blog using Simply Static (and other plugins) produced poor results. I quickly discovered that not all WordPress themes work well when converted to static HTML, and several of my plugins—especially those for tables, maps, comments, and contact forms—did not behave properly.</p>



<p class="wp-block-paragraph">After some research and experimentation, I found the <a href="https://wordpress.org/themes/neve/">Neve</a> theme to be lightweight, fast, and compatible with static-site generation. Along the way, I made several other improvements:</p>



<ul class="wp-block-list">
<li>Switched to the Neve theme</li>



<li>Merged two blogs (trailertravels.flanagan.io and kelly.flanagan.io) into one unified site, flanagan.io</li>



<li>Rebuilt tables as static HTML</li>



<li>Replaced the map plugin with <a href="https://wordpress.org/plugins/google-maps-easy/">Easy Google Maps</a></li>



<li>Removed comments and the contact form</li>



<li>Improved the overall look, feel, and usability</li>
</ul>



<p class="wp-block-paragraph">With these refinements in place, I was finally ready to generate a working static version of my site.</p>



<h3 class="wp-block-heading"><strong>Creating the Local Static Site</strong></h3>



<p class="wp-block-paragraph">I wanted each post’s featured image to appear when sharing its URL on social media. To achieve this, I added Open Graph (OG) tags to the header of every post. I implemented this by creating a PHP function and adding it to the Neve theme’s functions.php file.</p>



<p class="wp-block-paragraph">I modified Running the Simply Static plugin produces a folder containing all the files needed to host an equivalent static site. The plugin includes several configuration options, and I chose to use relative paths so that I could test the static site locally and deploy it anywhere without changing URLs.</p>



<p class="wp-block-paragraph">Simply Static required a root path of /, and I had to manually include a few additional files to ensure they were captured in the export. I also selected the option to include RSS related tags and the /feed/index.xml file. Otherwise, I left most defaults intact.</p>



<p class="wp-block-paragraph">I repeated the cycle many times: edit in WordPress → generate static version → test the result. This iterative process ensured that links, images, and media were all working as expected.</p>



<p class="wp-block-paragraph">To preview the static site locally, I used <a href="https://caddyserver.com/">Caddy</a>, a lightweight and secure web server. My Caddyfile looked like this:</p>



<pre class="wp-block-preformatted">flanagan.io {<br>    root * "/Users/kelly/Local Sites/flanaganio/app/curr_public_static"<br>    file_server<br>    tls internal<br>}</pre>



<p class="wp-block-paragraph">Before running Caddy, I added an entry in /etc/hosts mapping flanagan.io to 127.0.0.1. With that in place, I could open https://flanagan.io/ in a browser and inspect my static site just as it would appear online.</p>



<h3 class="wp-block-heading"><strong>Hosting the Static Site on AWS</strong></h3>



<p class="wp-block-paragraph">Because my blog serves a small audience—mostly family, friends, and a few curious readers—I wanted a hosting solution that was reliable, low-cost, and ideally free. Amazon Web Services (AWS) met those needs almost perfectly.</p>



<p class="wp-block-paragraph">I host my site using <a href="https://aws.amazon.com/s3/">AWS S3</a>, which stores the static files, and <a href="https://aws.amazon.com/cloudfront/">CloudFront</a>, which provides global content delivery and HTTPS support (S3 by itself only supports HTTP).</p>



<p class="wp-block-paragraph">I use two S3 buckets:</p>



<ul class="wp-block-list">
<li>One for flanagan.io, which stores and serves the site content.</li>



<li>A second for www.flanagan.io, which simply redirects to the main domain.</li>
</ul>



<p class="wp-block-paragraph">Other AWS services supporting my setup include:</p>



<ul class="wp-block-list">
<li><a href="https://aws.amazon.com/certificate-manager/">AWS Certificate Manager</a> – provides SSL/TLS certificates for HTTPS</li>



<li><a href="https://aws.amazon.com/route53/">Route 53</a> – manages domain DNS</li>



<li><a href="https://aws.amazon.com/iam/">Identity and Access Management (IAM)</a> – controls permissions</li>



<li><a href="https://aws.amazon.com/api-gateway/">API Gateway</a> and <a href="https://aws.amazon.com/sns/">Simple Notification Service (SNS)</a> – power my contact form</li>
</ul>


<div class="wp-block-image">
<figure class="alignright size-medium"><img decoding="async" width="300" height="208" src="/wp-content/uploads/2025/10/AWS-Cost-300x208.png" alt="" class="wp-image-3322" srcset="/wp-content/uploads/2025/10/AWS-Cost-300x208.png 300w, /wp-content/uploads/2025/10/AWS-Cost.png 623w" sizes="(max-width: 300px) 100vw, 300px" /></figure>
</div>


<p class="wp-block-paragraph">For September 2025, my total AWS cost was $0.59. Route 53’s base cost is $0.50/month, meaning file uploads and access requests accounted for only nine cents. Most of the other services fall comfortably within AWS’s free tier.</p>



<p class="wp-block-paragraph">When I first updated my blog, I would manually upload all of the static files to my S3 bucket every time I made a change. After waiting for the upload to finish, I also had to wait for CloudFront’s caches to refresh before anyone could see the updated content.</p>



<p class="wp-block-paragraph">I refined this workflow by creating a Makefile that leverages the AWS CLI to synchronize only files that have changed, rather than uploading the entire site every time. Previously, Simply Static touched all files in my site regardless of whether they were modified. This caused full-site uploads on each update, wasting time and increasing bandwidth costs.</p>



<p class="wp-block-paragraph">With the updated workflow, Simply Static now exports files to curr_public_static, which are then compared to those in prev_public_static. Files that differ are copied to diff_public_static, and only these files are uploaded to S3. This selective syncing significantly reduces upload time, bandwidth usage, and unnecessary overwrites.</p>



<p class="wp-block-paragraph">To ensure updates are immediately visible to visitors, the Makefile also automatically invalidates the relevant CloudFront caches. Additionally, I integrated git commands into the Makefile so that each update is backed up to my GitHub repository, providing both version control and a reliable off-site copy. Once the previous site is backed up, the files in curr_public_static are moved to prev_public_static to prepare for the next update. My Makefile is included at the end of this post.</p>



<h3 class="wp-block-heading"><strong>Contact Form</strong></h3>



<p class="wp-block-paragraph">To add a simple, serverless contact form, I combined HTML, CSS, and JavaScript with AWS’s API Gateway and SNS. The form sends a POST request to an API Gateway endpoint, which triggers SNS to email me the sender’s address, subject, and message. I also included an OPTIONS method to handle CORS preflight requests required by browsers. This approach eliminates the need for any backend server and, given the light usage, stays well within AWS’s free tier.</p>



<h3 class="wp-block-heading"><strong>Workflow</strong></h3>



<p class="wp-block-paragraph">My workflow is entirely manual but easy to follow:</p>



<ol class="wp-block-list">
<li>Open the LocalWP app on my laptop.</li>



<li>In a browser, open flanaganio.local and log in to WordPress.</li>



<li>Create or edit posts, upload media, and make any changes.</li>



<li>Run the Simply Static plugin to generate the static files.</li>



<li>Quit LocalWP.</li>



<li>Start Caddy and open flanagan.io in a browser to verify everything looks right.</li>



<li>Quit Caddy.</li>



<li>Run make deploy which executes several make targets. This converts the relative paths in /feed/index.xml to absolute paths, uploads any changed files to the S3 bucket and invalidates the CloudFront caches, ensuring that the latest content is immediately visible to visitors. It also make a backup, just in case.</li>
</ol>



<h3 class="wp-block-heading"><strong>Summary</strong></h3>



<p class="wp-block-paragraph">I successfully migrated my blog from a hosted WordPress service costing nearly $150<strong> per year</strong> to a self-hosted static site that costs less than $10 per year to operate. The move gave me:</p>



<ul class="wp-block-list">
<li>A cleaner, faster blog</li>



<li>Full control over my content</li>



<li>Lower ongoing costs</li>



<li>And a lot of satisfaction in learning something new</li>
</ul>



<p class="wp-block-paragraph">The result is exactly what I wanted—a simple, durable, and elegant home for my writing.</p>



<h3 class="wp-block-heading">Makefile</h3>



<pre class="wp-block-preformatted"># Directory paths<br>PREV_DIR := /Users/kelly/Local Sites/flanaganio/app/prev_public_static<br>CURR_DIR := /Users/kelly/Local Sites/flanaganio/app/curr_public_static<br>DIFF_DIR := /Users/kelly/Local Sites/flanaganio/app/diff_public_static<br>S3_BUCKET := s3://flanaganio-static/<br>CF_DISTRIBUTION_ID := E1JU16LZYIE94I<br>GITHUB_DIR := /Users/kelly/Local Sites/flanaganio/app/flanagan.io<br>LOCAL_DIR := $(PREV_DIR)<br>COMMIT_MSG := "Update static site $(shell date '+%Y-%m-%d %H:%M:%S')"<br><br># Rsync options<br>RSYNC_OPTS := -ac --delete --compare-dest="$(PREV_DIR)/"<br><br># Full deployment: diff, S3 upload, CloudFront, GitHub<br>deploy: fix_feed diff_dir s3_upload invalidate_cloudfront_caches github_copy curr_to_prev<br>	@echo "Deployment complete."<br><br># Compare current vs previous and generate diff directory<br>diff_dir:<br>	@echo "Comparing curr_public_static and prev_public_static"<br>	@rm -rf "$(DIFF_DIR)"<br>	@mkdir -p "$(DIFF_DIR)"<br>	@rsync $(RSYNC_OPTS) "$(CURR_DIR)/" "$(DIFF_DIR)/"<br>	@file_count=$$(find "$(DIFF_DIR)" -type f | wc -l | tr -d ' '); \<br>	total_size=$$(du -sh "$(DIFF_DIR)" | awk '{print $$1}'); \<br>	echo "Comparison complete."; \<br>	echo "Files copied to diff_public_static: $$file_count"; \<br>	echo "Total size of changed files: $$total_size"<br><br># Upload diff directory to S3<br>s3_upload:<br>	@echo "Uploading diff_public_static to $(S3_BUCKET)"<br>	@aws s3 sync "$(DIFF_DIR)/" "$(S3_BUCKET)" --exact-timestamps --quiet<br>	@echo "Upload complete."<br><br># Invalidate CloudFront caches<br>invalidate_cloudfront_caches:<br>	@echo "Creating CloudFront invalidation."<br>	@aws cloudfront create-invalidation --distribution-id "$(CF_DISTRIBUTION_ID)" --paths "/*" > /dev/null 2>&amp;1<br>	@echo "Invalidation request submitted."<br><br>github_copy:<br>	@echo "Syncing prev_public_static to GitHub."<br>	@rsync -a --delete --exclude ".git/" --exclude ".DS_Store" --quiet "$(LOCAL_DIR)/" "$(GITHUB_DIR)/"<br>	@cd "$(GITHUB_DIR)" &amp;&amp; \<br>	if [ -n "$$(git status --porcelain)" ]; then \<br>		UPDATED_COUNT=$$(git status --porcelain | wc -l | tr -d ' '); \<br>		git add . >/dev/null; \<br>		git commit -m "Update static site $$(date '+%Y-%m-%d %H:%M:%S')" >/dev/null; \<br>		git push --quiet origin main; \<br>		TOTAL_SIZE=$$(du -sh "$(GITHUB_DIR)" | awk '{print $$1}'); \<br>		echo "Updated $$UPDATED_COUNT files to GitHub (current size $$TOTAL_SIZE)."; \<br>	else \<br>		echo "No changes to commit."; \<br>	fi<br>	@echo "GitHub sync complete."<br><br># Copy all content from curr_public_static to prev_public_static<br>curr_to_prev:<br>	@echo "Copying content from curr_public_static to prev_public_static"<br>	@rsync -a --delete "$(CURR_DIR)/" "$(PREV_DIR)/"<br>	@echo "Copy complete."<br><br>fix_feed:<br>	@echo "Converting relative URLs to absolute in RSS feed."<br>	@sh -c "if [ -f '$(CURR_DIR)/feed/index.xml' ]; then sed -i '' -E \<br>		's|/wp-content/|https://flanagan.io/wp-content/|g; \<br>		 s|href=\"/|href=\"https://flanagan.io/|g; \<br>		 s|src=\"/|src=\"https://flanagan.io/|g; \<br>		 s|srcset=\"/|srcset=\"https://flanagan.io/|g; \<br>		 s|&lt;link>/|&lt;link>https://flanagan.io/|g' \<br>		'$(CURR_DIR)/feed/index.xml'; \<br>		echo 'RSS feed URLs updated safely.'; \<br>	else \<br>		echo 'RSS feed not found at $(CURR_DIR)/feed/index.xml'; \<br>	fi"<br><br># Clean diff directory<br>clean:<br>	@echo "Cleaning up diff directory"<br>	@rm -rf "$(DIFF_DIR)"<br>	@echo "Done."</pre>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Making an RV Fan Reversible</title>
		<link>/making-an-rv-fan-reversible/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 09 Jul 2023 01:10:08 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[Trailer Projects]]></category>
		<category><![CDATA[Electrical]]></category>
		<category><![CDATA[reversible]]></category>
		<guid isPermaLink="false">https://kelly.flanagan.io/?p=1421</guid>

					<description><![CDATA[Most, if not all, RVs have several vent fans on their roof. Our 2016 Outdoors RV 240 RKSB has one in our bedroom, one in the bathroom, and one in the kitchen. Our fans all have wall-mounted remotes that allow the fan speed to be adjusted, but our fans only draw air from the trailer&#8230;&#160;]]></description>
										<content:encoded><![CDATA[<div class="wp-block-image">
<figure class="alignright size-full is-resized"><a href="/wp-content/uploads/2023/07/Fan-on-top-of-trailer.jpeg"><img loading="lazy" decoding="async" width="849" height="565" src="/wp-content/uploads/2023/07/Fan-on-top-of-trailer.jpeg" alt="" class="wp-image-1415" style="width:240px;height:120px" srcset="/wp-content/uploads/2023/07/Fan-on-top-of-trailer.jpeg 849w, /wp-content/uploads/2023/07/Fan-on-top-of-trailer-300x200.jpeg 300w, /wp-content/uploads/2023/07/Fan-on-top-of-trailer-768x511.jpeg 768w" sizes="auto, (max-width: 849px) 100vw, 849px" /></a></figure>
</div>


<p class="wp-block-paragraph">Most, if not all, RVs have several vent fans on their roof. Our 2016 <a href="https://www.outdoorsrvmfg.com/">Outdoors RV</a> 240 RKSB has one in our bedroom, one in the bathroom, and one in the kitchen. Our fans all have wall-mounted remotes that allow the fan speed to be adjusted, but our fans only draw air from the trailer and exhaust it to the great outdoors. On many occasions, I have desired to draw air from outside and exhaust it into our living space. Many newer fans have this capability as a standard feature, but I was uninterested in the expense and labor of purchasing, installing, and sealing new units when our current fans were fine.</p>



<h2 class="wp-block-heading">Fan Basics</h2>


<div class="wp-block-image">
<figure class="alignright size-full is-resized"><a href="/wp-content/uploads/2023/07/Basic-Motor-Circuit.png"><img loading="lazy" decoding="async" width="938" height="706" src="/wp-content/uploads/2023/07/Basic-Motor-Circuit.png" alt="" class="wp-image-1410" style="width:240px" srcset="/wp-content/uploads/2023/07/Basic-Motor-Circuit.png 938w, /wp-content/uploads/2023/07/Basic-Motor-Circuit-300x226.png 300w, /wp-content/uploads/2023/07/Basic-Motor-Circuit-768x578.png 768w" sizes="auto, (max-width: 938px) 100vw, 938px" /></a></figure>
</div>


<p class="wp-block-paragraph">A basic controllable fan circuit consists of a DC motor M, a DC voltage source V<sub>S</sub> and a switch S. A fan of appropriate size and style is then connected to the motor shaft. When the switch is depressed, the motor spins, and the connected fan moves air. </p>


<div class="wp-block-image">
<figure class="alignleft size-full is-resized"><a href="/wp-content/uploads/2023/07/Fan-Switch.png"><img loading="lazy" decoding="async" width="980" height="692" src="/wp-content/uploads/2023/07/Fan-Switch.png" alt="" class="wp-image-1417" style="width:240px" srcset="/wp-content/uploads/2023/07/Fan-Switch.png 980w, /wp-content/uploads/2023/07/Fan-Switch-300x212.png 300w, /wp-content/uploads/2023/07/Fan-Switch-768x542.png 768w" sizes="auto, (max-width: 980px) 100vw, 980px" /></a></figure>
</div>


<p class="wp-block-paragraph">Our current RV fan is only slightly more complicated than the basic circuit described above. The constant DC voltage source depicted in the previous figure is replaced by a variable or <a href="https://en.wikipedia.org/wiki/Pulse-width_modulation">pulse width modulated</a> DC voltage source V<sub>V</sub> and the switch is replaced with a push button switch S<sub>C</sub> that completes the circuit and drives the motor and fan M<sub>F</sub> when the fan cover is open.</p>


<div class="wp-block-image">
<figure class="alignright size-full is-resized"><a href="/wp-content/uploads/2023/07/Fan-DPDT.png"><img loading="lazy" decoding="async" width="1408" height="786" src="/wp-content/uploads/2023/07/Fan-DPDT.png" alt="" class="wp-image-1413" style="width:240px" srcset="/wp-content/uploads/2023/07/Fan-DPDT.png 1408w, /wp-content/uploads/2023/07/Fan-DPDT-300x167.png 300w, /wp-content/uploads/2023/07/Fan-DPDT-1024x572.png 1024w, /wp-content/uploads/2023/07/Fan-DPDT-768x429.png 768w" sizes="auto, (max-width: 1408px) 100vw, 1408px" /></a></figure>
</div>


<p class="wp-block-paragraph">DC motors are easily reversed by reversing the polarity of their power source. This is easily accomplished using a <a href="https://en.wikipedia.org/wiki/Switch">double-pole double-throw (DPDT) switch</a>, as shown in the figure. By adding the DPDT switch S<sub>DPDT</sub> after the voltage source V<sub>V</sub> and switch S<sub>C</sub>, we don&#8217;t have to concern ourselves with how and when the appropriate power is delivered; we simply need to provide it to the motor M<sub>F</sub> in one of two directions. With the switch in the upper position, a positive voltage is connected to the upper motor connection, and the negative source voltage is connected to the lower motor terminal. When the DPDT switch is in the lower position, the polarity is reversed.</p>



<h2 class="wp-block-heading">Our Implementation</h2>


<div class="wp-block-image">
<figure class="alignright size-full is-resized"><a href="/wp-content/uploads/2023/07/Fan-in-Ceiling-Torn-Apart.jpeg"><img loading="lazy" decoding="async" width="2522" height="1817" src="/wp-content/uploads/2023/07/Fan-in-Ceiling-Torn-Apart.jpeg" alt="" class="wp-image-1414" style="width:240px" srcset="/wp-content/uploads/2023/07/Fan-in-Ceiling-Torn-Apart.jpeg 2522w, /wp-content/uploads/2023/07/Fan-in-Ceiling-Torn-Apart-300x216.jpeg 300w, /wp-content/uploads/2023/07/Fan-in-Ceiling-Torn-Apart-1024x738.jpeg 1024w, /wp-content/uploads/2023/07/Fan-in-Ceiling-Torn-Apart-768x553.jpeg 768w, /wp-content/uploads/2023/07/Fan-in-Ceiling-Torn-Apart-1536x1107.jpeg 1536w, /wp-content/uploads/2023/07/Fan-in-Ceiling-Torn-Apart-2048x1476.jpeg 2048w" sizes="auto, (max-width: 2522px) 100vw, 2522px" /></a></figure>
</div>


<p class="wp-block-paragraph">A fun part of every project is tearing things up and being creative. After removing the internal trim of the fan box and the fan cover, it became apparent that this project would be easier than expected. There was plenty of room on every side of the fan to accommodate an additional switch, and the wiring was straightforward. </p>


<div class="wp-block-image">
<figure class="alignleft size-full is-resized"><a href="/wp-content/uploads/2023/07/DPDT-Switch.png"><img loading="lazy" decoding="async" width="1128" height="1148" src="/wp-content/uploads/2023/07/DPDT-Switch.png" alt="" class="wp-image-1426" style="width:230px;height:240px" srcset="/wp-content/uploads/2023/07/DPDT-Switch.png 1128w, /wp-content/uploads/2023/07/DPDT-Switch-295x300.png 295w, /wp-content/uploads/2023/07/DPDT-Switch-1006x1024.png 1006w, /wp-content/uploads/2023/07/DPDT-Switch-768x782.png 768w" sizes="auto, (max-width: 1128px) 100vw, 1128px" /></a></figure>
</div>


<p class="wp-block-paragraph">With plenty of available space, I selected a DPDT switch with appropriate voltage and current characteristics. I knew from previous measurements that our fans draw far less than 10 A of current and run off the 12 V supply. I chose a <a href="https://www.amazon.com/gp/product/B08DKGCX9H/ref=ppx_yo_dt_b_asin_title_o01_s00?ie=UTF8&amp;psc=1">rocker switch</a> that met these requirements and has a low profile. Notice that this switch has six blade-type connections. The center two connections are connected to two outer connections in position one and the other two outer connections in position two. We connect our variable voltage source to the center two connections and then wire the fan motor to the others.</p>


<div class="wp-block-image">
<figure class="alignright size-full is-resized"><a href="/wp-content/uploads/2023/07/Fan-Control-Board-scaled-1.jpeg"><img loading="lazy" decoding="async" width="2560" height="2241" src="/wp-content/uploads/2023/07/Fan-Control-Board-scaled-1.jpeg" alt="" class="wp-image-1412" style="width:240px" srcset="/wp-content/uploads/2023/07/Fan-Control-Board-scaled-1.jpeg 2560w, /wp-content/uploads/2023/07/Fan-Control-Board-scaled-1-300x263.jpeg 300w, /wp-content/uploads/2023/07/Fan-Control-Board-scaled-1-1024x896.jpeg 1024w, /wp-content/uploads/2023/07/Fan-Control-Board-scaled-1-768x672.jpeg 768w, /wp-content/uploads/2023/07/Fan-Control-Board-scaled-1-1536x1345.jpeg 1536w, /wp-content/uploads/2023/07/Fan-Control-Board-scaled-1-2048x1793.jpeg 2048w" sizes="auto, (max-width: 2560px) 100vw, 2560px" /></a></figure>
</div>


<p class="wp-block-paragraph">The two wires that connect to the fan motor come from the fan controller illustrated in the figure on the right. The red and white wires of interest were easily traced around the fan housing, up through the fan box, and across one of the cross-arms holding the motor in place. </p>


<div class="wp-block-image">
<figure class="alignleft size-full is-resized"><a href="/wp-content/uploads/2023/07/Fan-Power-and-Cover-Switch-e1688859923886.jpeg"><img loading="lazy" decoding="async" width="629" height="697" src="/wp-content/uploads/2023/07/Fan-Power-and-Cover-Switch-e1688859923886.jpeg" alt="" class="wp-image-1416" style="width:230px;height:240px" srcset="/wp-content/uploads/2023/07/Fan-Power-and-Cover-Switch-e1688859923886.jpeg 629w, /wp-content/uploads/2023/07/Fan-Power-and-Cover-Switch-e1688859923886-271x300.jpeg 271w" sizes="auto, (max-width: 629px) 100vw, 629px" /></a></figure>
</div>


<p class="wp-block-paragraph">In the following figure, you can easily see the same red and white wires. As previously mentioned, these wires come from the fan controller and up through the fan box, across a cross-arm, and connect to the motor. Notice that the white wire goes through a silver cylinder which is the switch that completes the circuit when the fan cover is open.</p>



<p class="wp-block-paragraph">While our initial intention was to wire our implementation according to the schematics previously discussed, it would have been much more challenging to get to the wiring on the motor side of the fan cover switch. While our wiring doesn&#8217;t match the presented schematics, it is functionally equivalent. The fan cover switch is connected to one of the motor terminals, while the other terminal of the fan cover switch is divided and attached to the DPDT switch. </p>


<div class="wp-block-image">
<figure class="alignright size-full is-resized"><a href="/wp-content/uploads/2023/07/Wiring-on-back-of-DPDT-scaled-1.jpeg"><img loading="lazy" decoding="async" width="2560" height="2316" src="/wp-content/uploads/2023/07/Wiring-on-back-of-DPDT-scaled-1.jpeg" alt="" class="wp-image-1420" style="width:240px;height:220px" srcset="/wp-content/uploads/2023/07/Wiring-on-back-of-DPDT-scaled-1.jpeg 2560w, /wp-content/uploads/2023/07/Wiring-on-back-of-DPDT-scaled-1-300x271.jpeg 300w, /wp-content/uploads/2023/07/Wiring-on-back-of-DPDT-scaled-1-1024x926.jpeg 1024w, /wp-content/uploads/2023/07/Wiring-on-back-of-DPDT-scaled-1-768x695.jpeg 768w, /wp-content/uploads/2023/07/Wiring-on-back-of-DPDT-scaled-1-1536x1390.jpeg 1536w, /wp-content/uploads/2023/07/Wiring-on-back-of-DPDT-scaled-1-2048x1853.jpeg 2048w" sizes="auto, (max-width: 2560px) 100vw, 2560px" /></a></figure>
</div>


<p class="wp-block-paragraph">We cut the red and white wires. The pair of wires from the fan controller are connected to the center two connections on our DPDT rocker switch. These two connections were made with crimp-on blue spade connectors and can be seen in the figure to the right. The red and white wires that go up to the fan motor are doubled, resulting in two red wires and two black wires. We changed from white to black because I didn&#8217;t have any white wire. These connections were made using <a href="https://www.amazon.com/gp/product/B07GDDKJ1D/ref=ppx_yo_dt_b_search_asin_title?ie=UTF8&amp;psc=1">solder seal wire connectors</a>; these things are amazing. These pairs of wires can be seen in the figure. One pair is connected to an outer pair of contacts on the rocker switch, while the other pair is connected to the remaining outer contacts in the opposite direction. These connections were also made with crimp-on spade connectors.</p>


<div class="wp-block-image">
<figure class="alignleft size-full is-resized"><a href="/wp-content/uploads/2023/07/DPDT-and-Wiring-scaled-1.jpeg"><img loading="lazy" decoding="async" width="2045" height="2560" src="/wp-content/uploads/2023/07/DPDT-and-Wiring-scaled-1.jpeg" alt="" class="wp-image-1411" style="width:200px;height:240px" srcset="/wp-content/uploads/2023/07/DPDT-and-Wiring-scaled-1.jpeg 2045w, /wp-content/uploads/2023/07/DPDT-and-Wiring-scaled-1-240x300.jpeg 240w, /wp-content/uploads/2023/07/DPDT-and-Wiring-scaled-1-818x1024.jpeg 818w, /wp-content/uploads/2023/07/DPDT-and-Wiring-scaled-1-768x961.jpeg 768w, /wp-content/uploads/2023/07/DPDT-and-Wiring-scaled-1-1227x1536.jpeg 1227w, /wp-content/uploads/2023/07/DPDT-and-Wiring-scaled-1-1636x2048.jpeg 1636w" sizes="auto, (max-width: 2045px) 100vw, 2045px" /></a></figure>
</div>


<p class="wp-block-paragraph">The rectangular hole for the rocker switch was made in the thin plastic fan trim with a sharp chisel. It is essential to cut the initial hole small and then increase the size slowly while repeatedly trying to snap the switch in place. It&#8217;s much easier to make the hole slightly larger than smaller! </p>



<p class="wp-block-paragraph">The switch was snapped in place before the wiring was finalized so wires could be appropriately routed. The mounted switch and the associated wiring can be seen in the figure to the left. </p>


<div class="wp-block-image">
<figure class="alignright size-full is-resized"><a href="/wp-content/uploads/2023/07/Finished-scaled-1.jpeg"><img loading="lazy" decoding="async" width="2560" height="1551" src="/wp-content/uploads/2023/07/Finished-scaled-1.jpeg" alt="" class="wp-image-1418" style="width:240px;height:145px" srcset="/wp-content/uploads/2023/07/Finished-scaled-1.jpeg 2560w, /wp-content/uploads/2023/07/Finished-scaled-1-300x182.jpeg 300w, /wp-content/uploads/2023/07/Finished-scaled-1-1024x620.jpeg 1024w, /wp-content/uploads/2023/07/Finished-scaled-1-768x465.jpeg 768w, /wp-content/uploads/2023/07/Finished-scaled-1-1536x931.jpeg 1536w, /wp-content/uploads/2023/07/Finished-scaled-1-2048x1241.jpeg 2048w" sizes="auto, (max-width: 2560px) 100vw, 2560px" /></a></figure>
</div>


<p class="wp-block-paragraph">After ensuring everything worked as expected, the wiring was neatly tucked away, and the fan cover and trim were replaced. The final product can be seen in the figure to the right.</p>



<p class="wp-block-paragraph">With a few connectors, a couple of feet of wire, a $3 switch, and an hour of time, I was able to make my RV fan reversible. The result looks fine, works great, and saves me time and money in the long run.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RV Power Center: Performance</title>
		<link>/rv-power-center-performance/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 04 May 2022 00:34:07 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[Trailer Projects]]></category>
		<category><![CDATA[Electrical]]></category>
		<category><![CDATA[Power]]></category>
		<category><![CDATA[Power Center]]></category>
		<category><![CDATA[RV Power]]></category>
		<category><![CDATA[Solar]]></category>
		<category><![CDATA[Solar Power]]></category>
		<category><![CDATA[Victron]]></category>
		<guid isPermaLink="false">https://kelly.flanagan.io/?p=1393</guid>

					<description><![CDATA[This is the tenth and last post describing our RV power system. Our previous post described the final design and some of its characteristics. This post summarizes the system&#8217;s performance on our first overnight outing. First, for convenience, we briefly describe the final system. Next, we describe our outing and associated conditions and finally explain&#8230;&#160;]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">This is the tenth and last post describing our RV power system. Our <a href="/rv-power-center-final-results/" data-type="link" data-id="/rv-power-center-final-results/">previous post</a> described the final design and some of its characteristics. This post summarizes the system&#8217;s performance on our first overnight outing. First, for convenience, we briefly describe the final system. Next, we describe our outing and associated conditions and finally explain the system&#8217;s performance.</p>



<h2 class="wp-block-heading" id="final-system">Final System</h2>



<p class="wp-block-paragraph">Our power system fits within the left pass-through storage area, illustrated in Figure 1.</p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2022/02/Complete-System-scaled-2.jpeg"><img loading="lazy" decoding="async" width="300" height="242" src="/wp-content/uploads/2022/02/Complete-System-scaled-2-300x242.jpeg" alt="" class="wp-image-1344" srcset="/wp-content/uploads/2022/02/Complete-System-scaled-2-300x242.jpeg 300w, /wp-content/uploads/2022/02/Complete-System-scaled-2-1024x825.jpeg 1024w, /wp-content/uploads/2022/02/Complete-System-scaled-2-768x619.jpeg 768w, /wp-content/uploads/2022/02/Complete-System-scaled-2-1536x1237.jpeg 1536w, /wp-content/uploads/2022/02/Complete-System-scaled-2-2048x1650.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 1 illustrates our complete power center providing 800 W of solar, 360 Ah of Lithium-ion batteries, and a 3kVA invert/charger.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Figure 1 illustrates the major components of our system. There are seven major components illustrated from upper left to lower right:</p>



<ul class="wp-block-list">
<li>Solar PV disconnect switch</li>



<li>Victron SmartSolar 150/45 solar charger</li>



<li>Victron MultiPlus-II 2x 120V inverter/charger</li>



<li>Victron Cerbo GX monitoring system</li>



<li>Victron SmartShunt</li>



<li>Blue Sea battery switch</li>



<li>Victron Lynx Distributor</li>
</ul>



<p class="wp-block-paragraph">Our 360 Ah battery bank is behind and to the right of this location. The solar charger and the SmartShunt attach to the Cerbo GX via VE.Direct cables. The battery voltage monitor (mounted on the battery bank) and the MultiPlus-II connect to the Cerbo GX via two VE.Bus cables.</p>



<h2 class="wp-block-heading">Our Outing &#8211; Red Canyon, Utah</h2>



<p class="wp-block-paragraph">We spent two nights in Red Canyon Campground in southern Utah in late April. This outing is described in more detail in another <a href="/red-canyon-campground-utah/">post</a>. The daytime temperatures were in the mid-60s, and the lows were in the low-20s. The sun was bright the first day. We had a couple of hours of good sunlight on the second day and then overcast with rain.</p>



<h2 class="wp-block-heading">Performance</h2>



<p class="wp-block-paragraph">With the nighttime temperatures in the 20s, our furnace periodically ran to keep the trailer at approximately 65 degrees. In addition, we watched television for several hours at night, used lights, and charged a couple of phones, watches, and an iPad. With all of these devices running and charging, we consumed nearly 80 Ah of our 360 Ah battery bank. Our batteries were replenished after just a few hours of good sunlight.</p>



<p class="wp-block-paragraph">Early in the day, the solar charging system produced about 360 W. I decided to check the cleanliness of the solar panels and was shocked to find them coated in mud. It was thick enough that I could not remove it without a significant amount of water. After cleaning the panels, the system produced just over 500 W. A little water and elbow grease pay off.</p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2022/05/Fireplace-scaled-2.jpeg"><img loading="lazy" decoding="async" width="300" height="225" src="/wp-content/uploads/2022/05/Fireplace-scaled-2-300x225.jpeg" alt="" class="wp-image-1407" srcset="/wp-content/uploads/2022/05/Fireplace-scaled-2-300x225.jpeg 300w, /wp-content/uploads/2022/05/Fireplace-scaled-2-1024x768.jpeg 1024w, /wp-content/uploads/2022/05/Fireplace-scaled-2-768x576.jpeg 768w, /wp-content/uploads/2022/05/Fireplace-scaled-2-1536x1152.jpeg 1536w, /wp-content/uploads/2022/05/Fireplace-scaled-2-2048x1536.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 2, our electric fireplace.</figcaption></figure>
</div>


<p class="wp-block-paragraph">After a 5 mile hike, we returned to find our RV an uncomfortable 81 degrees. We flipped on the AC and set the thermostat to 75. The AC drew a constant 1100 W and ran for approximately 30 minutes. Later that evening, the temperature in the RV dipped down to about 68 while we were still up and around, so we turned on the electric fireplace. That unit drew nearly 1400 W but warmed us right up. We tried a few other electric devices to see the practicality. The refrigerator on electric power drew about 22 A, my wife&#8217;s curling iron was no big deal at 200 W, and I&#8217;ve tried the microwave before at just over 1000 W. </p>



<p class="wp-block-paragraph">It is a pleasure to use all of our systems without generating noise. We can use the AC, microwave, and TV after campground quiet hours without worrying about bothering others. However, it is funny watching us adapt to this new world. Are we content toasting our bread in the broiler? Of course not; we need a toaster because we can have one! I am sure we&#8217;ll add a hairdryer and who knows what else. Nevertheless, I am pleased with the outcome and the comfort it has added to our lives.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RV Power Center: Final Results</title>
		<link>/rv-power-center-final-results/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 04 Feb 2022 02:20:18 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[Trailer Projects]]></category>
		<category><![CDATA[Batteries]]></category>
		<category><![CDATA[Battery Bank]]></category>
		<category><![CDATA[Lion Energy]]></category>
		<category><![CDATA[Lithium-Ion Battery]]></category>
		<category><![CDATA[ORV]]></category>
		<category><![CDATA[Power]]></category>
		<category><![CDATA[Power Center]]></category>
		<category><![CDATA[Solar Power]]></category>
		<category><![CDATA[Victron]]></category>
		<guid isPermaLink="false">https://kelly.flanagan.io/?p=1340</guid>

					<description><![CDATA[This is the ninth post of a series of articles documenting and describing our RV electrical upgrade. Our previous post in this series described a simplified model of our battery bank, the wiring of our system, the resistance contributed by each component and associated cables, and the expected system voltage drop. Our goal is to&#8230;&#160;]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph" id="block-b42d4e54-bdd5-4922-aab8-88d00d8c4719">This is the ninth post of a series of articles documenting and describing our RV electrical upgrade. Our <a href="/rv-power-center-voltage-drop/">previous post</a> in this series described a simplified model of our battery bank, the wiring of our system, the resistance contributed by each component and associated cables, and the expected system voltage drop. Our goal is to keep our voltage drop to 2.5% or less as recommended in <a href="https://www.victronenergy.com/upload/documents/Wiring-Unlimited-EN.pdf">Victron&#8217;s Wiring Unlimited</a>. This post describes the outcome, reports actual voltage drop measurements, and compares these with those calculated previously. Finally, we evaluate our final results regarding our initial goals, point out a few things we&#8217;d do differently, and conclude. For those interested, this <a href="/rv-power-center-parts-tools-and-equipment/">page</a> lists the parts, equipment, and tools we used to build our power system.</p>



<h2 class="wp-block-heading" id="block-223faa43-62b6-4aa0-959f-b4f85dda77dc">Initial Design</h2>


<div class="wp-block-image is-resized">
<figure class="alignleft" id="block-1c59a3f4-5d25-444a-96d3-b3f4574385f1"><img decoding="async" src="/wp-content/uploads/2022/01/12-V-Design-v4.png" alt="This image has an empty alt attribute; its file name is 12-V-Design-v4.png" style="width:400px"/><figcaption class="wp-element-caption">Figure 1 illustrates the power system proposed in a <a href="/rv-power-center-design/">previous post</a>.</figcaption></figure>
</div>


<p class="wp-block-paragraph" id="block-a3dd66d5-f46d-4fd1-981a-3a877cd1acb2">The power system we built, illustrated in Figure 1, was initially proposed in <a href="/rv-power-center-design/">one of our first posts</a> in this series. In our <a href="/rv-power-center-voltage-drop/">previous post</a>, we introduced the critical path of this system consisting of the circuit from the battery bank to the inverter/charger and back, illustrated in Figure 2.</p>


<div class="wp-block-image is-resized">
<figure class="alignright" id="block-83c3a9f4-aa73-42a1-9b03-bfff784280fe"><img decoding="async" src="/wp-content/uploads/2022/02/Final-Critical-Path-Schematic-1-1024x714.png" alt="This image has an empty alt attribute; its file name is Final-Critical-Path-Schematic-1024x714.png" style="width:400px"/><figcaption class="wp-element-caption">Figure 2 illustrates the components and cables that make up our system&#8217;s critical path and associated resistance values.</figcaption></figure>
</div>


<p class="wp-block-paragraph" id="block-05a554a4-0863-499a-94f7-4751f57c6188">Figure 2 includes the measured resistance of each cable and component, such as the 400 A class T fuse, battery disconnect switch, shunt, 400 A mega fuse, and the Lynx Distributor busbar system. These resistances are assumed to be worst-case values as we rounded up measurements and the measurement device&#8217;s connection to each component was simply the tension applied by the spring-loaded probes. The total measured resistance of components and cables around our system&#8217;s critical path is 1.77 mΩ. With this resistance, we concluded that our system should be capable of providing just over 180 A while remaining at or below our 2.5% voltage drop goal.</p>



<h2 class="wp-block-heading" id="final-system">Final System</h2>



<p class="wp-block-paragraph">After considerable cold winter work, our design came to fruition. As previously described, our power system fits within the left pass-through storage area, illustrated in Figure 3.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-full"><a href="/wp-content/uploads/2022/02/Complete-System-scaled-2.jpeg"><img decoding="async" src="/wp-content/uploads/2022/02/Complete-System-scaled-2.jpeg" alt="" class="wp-image-1343" style="width:400px"/></a><figcaption class="wp-element-caption">Figure 3 illustrates our complete power center providing 800 W of solar, 360 Ah of Lithium-ion batteries, and a 3kVA invert/charger.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Figure 3 illustrates the major components of our system. There are seven major components illustrated from upper left to lower right:</p>



<ul class="wp-block-list">
<li>Solar PV disconnect switch</li>



<li>Victron SmartSolar 150/45 solar charger</li>



<li>Victron MultiPlus-II 2x 120V inverter/charger</li>



<li>Victron Cerbo GX monitoring system</li>



<li>Victron SmartShunt</li>



<li>Blue Sea battery switch</li>



<li>Victron Lynx Distributor</li>
</ul>



<p class="wp-block-paragraph">Our battery bank is behind and to the right of this location. The solar charger and the SmartShunt attach to the Cerbo GX via VE.Direct cables. The battery voltage monitor (mounted on the battery bank) and the MultiPlus-II connect to the Cerbo GX via two VE.Bus cables.</p>



<p class="wp-block-paragraph">We used a Victron MK3-USB device to program the inverter/charger for our specific setup and then used the remote console provided by the Cerbo GX to monitor the initial startup. After turning on the battery switch and the solar PV switch, the system immediately started providing inverted power to the RV, and the solar charger started charging the batteries. Next, using a halogen light and my wife&#8217;s toaster, we applied some moderate load to the system and took some readings, found in Table 1.</p>



<table style="width:100%; border-collapse: collapse; text-align: left; color: white;">
	<thead style="background-color: #293d47;">
		<tr>
			<th style="padding: 8px; border: 1px solid #ccc;">Battery Voltage</th>
			<th style="padding: 8px; border: 1px solid #ccc;">Inverter Voltage</th>
			<th style="padding: 8px; border: 1px solid #ccc;">Voltage Drop</th>
			<th style="padding: 8px; border: 1px solid #ccc;">Current (A)</th>
			<th style="padding: 8px; border: 1px solid #ccc;">Resistance mΩ</th>
		</tr>
	</thead>
	<tbody>
		<tr style="background-color: #798d97;">
			<td style="padding: 8px; border: 1px solid #ccc;">12.88</td>
			<td style="padding: 8px; border: 1px solid #ccc;">12.84</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.04</td>
			<td style="padding: 8px; border: 1px solid #ccc;">25</td>
			<td style="padding: 8px; border: 1px solid #ccc;">1.6</td>
		</tr>
		<tr style="background-color: #596d77;">
			<td style="padding: 8px; border: 1px solid #ccc;">12.71</td>
			<td style="padding: 8px; border: 1px solid #ccc;">12.61</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.10</td>
			<td style="padding: 8px; border: 1px solid #ccc;">73</td>
			<td style="padding: 8px; border: 1px solid #ccc;">1.4</td>
		</tr>
		<tr style="background-color: #798d97;">
			<td style="padding: 8px; border: 1px solid #ccc;">12.28</td>
			<td style="padding: 8px; border: 1px solid #ccc;">12.04</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.24</td>
			<td style="padding: 8px; border: 1px solid #ccc;">157</td>
			<td style="padding: 8px; border: 1px solid #ccc;">1.5</td>
		</tr>
	</tbody>
</table>




<p class="wp-block-paragraph">As expected, as the system current increases, the voltage drop experienced by the inverter/charger increases. We divided the voltage drop by the associated system current to calculate the system resistance. Averaging these three values, we note that the system resistance is 1.5 mΩ which is 0.27 mΩ lower than the measured 1.77 mΩ.</p>



<p class="wp-block-paragraph">The system experienced a 0.24 V voltage drop with a 157 A load. A voltage drop of 0.24 V is a percentage voltage drop of just 1.9%, well below our limit of 2.5%. With a resistance of only 1.5 mΩ, we should be able to load our system to nearly 215 A without exceeding our 2.5% goal. These 5-10 minute load tests resulted in almost no heat generation by the inverter/charger or any system components. I am looking forward to more extended<span style="font-size: revert;"> tests to see how hot things get. </span></p>



<h2 class="wp-block-heading" id="summary-how-did-we-do">Summary: How Did We Do</h2>



<p class="wp-block-paragraph">Nearly three months ago, we outlined our goals for our new power center in our <a href="/rv-electrical-upgrade/">first </a><a href="/rv-electrical-upgrade/">p</a><a href="/rv-electrical-upgrade/">ost on this subject</a>. We desired the ability to use our microwave, television, and other 120 V AC systems without having to ruin our camping solitude with a generator. In addition, we wanted to minimize the intrusion of our generator while recharging our batteries. We determined that to meet our needs, we needed several items:</p>



<ul class="wp-block-list">
<li>400 Ah of lithium-ion batteries</li>



<li>800 Watts of solar power</li>



<li>An inverter that is capable of producing nearly 3000 Watts of 120 V AC power</li>



<li>A battery charger that is capable of consuming our entire generator output to minimize charge time</li>
</ul>



<p class="wp-block-paragraph">We have nearly met each of these requirements. Instead of 400 Ah of batteries, we have 360 Ah, and instead of 3000 W of inverter power, we have 3000 VA or 2400 W continuous. We believe each is close enough to call this project a success. Perhaps more importantly, we learned a lot on the journey and had a lot of fun. If our RV needs to be restored to what we had before this project, <a href="/rv-power-center-return-to-factory-default/">here</a> is a brief description of the required tasks.</p>



<p class="wp-block-paragraph">We did a couple of things right and a few we&#8217;d do differently with the new knowledge we possess:</p>



<ol class="wp-block-list">
<li>We can&#8217;t properly express how great the <a href="https://shop.explorist.life/shop/all-products/connectors/victron-lynx-adapter/">copper bar approach</a> to connecting the battery disconnect switch and the SmartShunt to the Victron Lynx Distributor is. Using a short segment of 4/0 wire and a lug at each end results in a rather long connection. The copper bar approach saves space, looks clean, and in our cramped environment made our layout possible. You could save ten bucks if you want to make your own, but we saved ourselves the cutting, drilling, and the likely mistakes and <a href="https://shop.explorist.life/shop/all-products/connectors/victron-lynx-adapter/">bought a pair</a>.</li>



<li>I wouldn&#8217;t have initially skimped on our torque wrench purchase. Our fitst purchase had a torqu range of 10-100 ft-lbs and barely registered when being used at the low end. We ended up twisting a bolt head on a battery lug clean off. This was dangerous and could have resulted in a bolt being unretrievable from an expensive battery. Fortunately, just enough bolt was left to enable its removal with a pair of vicegrips. We love our second torque wrench, the <a href="https://www.amazon.com/gp/product/B01N0XWS64/ref=ppx_yo_dt_b_asin_title_o05_s00?ie=UTF8&amp;psc=1">Park Tool TW-6.2</a>.</li>



<li>We would definitely use boat/marine wire instead of the 6/3 Romex that we installed. Our RV, like most, is full of Romex making us comfortable that this was a reasonable choice. In addition, 6/3 Romex contains stranded conductors, but not like ultra flexible boat/marine wire such as <a href="https://www.ancorproducts.com/en/p/130710">Ancor&#8217;s Triplex Cable</a>.</li>



<li>We would have used lugs suggested by Victron Energy. The 4/0 sized lugs we used are great, but don&#8217;t fit very well within the Victron Lynx Distributor. I suspect, but have no evidence that the lugs they suggest would fit much better.</li>
</ol>



<p class="wp-block-paragraph">We&#8217;re done, it looks clean and neat, and above all else, it works!</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RV Power Center: Voltage Drop</title>
		<link>/rv-power-center-voltage-drop/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 28 Jan 2022 04:02:07 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[Trailer Projects]]></category>
		<category><![CDATA[Resistance]]></category>
		<category><![CDATA[Victron]]></category>
		<category><![CDATA[Voltage Drop]]></category>
		<category><![CDATA[Voltage Ripple]]></category>
		<guid isPermaLink="false">https://kelly.flanagan.io/?p=1238</guid>

					<description><![CDATA[This post is the eighth of an ongoing series of articles documenting and describing our RV electrical upgrade. Our previous post in this series described some non-power-related improvements to the pass-through storage area. These improvements included thermal insulation and an acquired storage system. In this post, we describe a simplified model of our battery bank,&#8230;&#160;]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">This post is the eighth of an ongoing series of articles documenting and describing our RV electrical upgrade. Our <a href="/rv-power-center-wiring/">previous post</a> in this series described some non-power-related improvements to the pass-through storage area. These improvements included thermal insulation and an acquired storage system. In this post, we describe a simplified model of our battery bank, the wiring of our system, the resistance contributed by each component and associated cables, and the expected system voltage drop. Our goal is to keep our voltage drop to 2.5% or less as recommended in <a href="https://www.victronenergy.com/upload/documents/Wiring-Unlimited-EN.pdf">Victron&#8217;s Wiring Unlimited</a>.</p>



<h2 class="wp-block-heading" id="our-battery-bank">Our Battery Bank</h2>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2022/01/24-V-Schematic.jpg"><img loading="lazy" decoding="async" width="300" height="169" src="/wp-content/uploads/2022/01/24-V-Schematic-300x169.jpg" alt="" class="wp-image-1246" srcset="/wp-content/uploads/2022/01/24-V-Schematic-300x169.jpg 300w, /wp-content/uploads/2022/01/24-V-Schematic-1024x576.jpg 1024w, /wp-content/uploads/2022/01/24-V-Schematic-768x432.jpg 768w, /wp-content/uploads/2022/01/24-V-Schematic.jpg 1365w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 1 illustrates the Halfway parallel battery configuration.</figcaption></figure>
</div>


<p class="wp-block-paragraph">We previously discussed the idea of installing a 24 V system to reduce system currents, but we have determined to stay with a 12 V system. A 12 V system keeps things straightforward and reduces our time to completion. We&#8217;ll use the &#8220;Halfway&#8221; parallel configuration for our battery bank as described in <a href="https://www.victronenergy.com/upload/documents/Wiring-Unlimited-EN.pdf">Wiring Unlimited</a> and illustrated in Figure 1. We chose this approach because it simplifies the cable layout given the physical placement of our batteries.</p>



<p class="wp-block-paragraph">The Halfway configuration ensures the circuit path from each battery&#8217;s positive terminal, through an otherwise balanced load, and back to the same battery&#8217;s negative terminal is the same length for each battery. Strictly speaking, the resistance, measured in ohms (Ω), should be kept equivalent and minimal, but length is correlated to resistance and is easier to measure. Our design will opt for wiring convenience over strict adherence to keeping each path equal in length. Using wires of various lengths will introduce minor deviations from the ideal.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2025/08/Thevenin-Model-of-Battery-768x704-1.png"><img loading="lazy" decoding="async" width="300" height="275" src="/wp-content/uploads/2025/08/Thevenin-Model-of-Battery-768x704-1-300x275.png" alt="" class="wp-image-1652" srcset="/wp-content/uploads/2025/08/Thevenin-Model-of-Battery-768x704-1-300x275.png 300w, /wp-content/uploads/2025/08/Thevenin-Model-of-Battery-768x704-1.png 768w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 2 illustrates a simple battery model consisting of an ideal/imaginary battery and a resistor representing the internal resistance of a real-world battery.</figcaption></figure>
</div>


<p class="wp-block-paragraph">We developed a simplified <a href="https://en.wikipedia.org/wiki/Th%C3%A9venin%27s_theorem">model</a> of our battery bank to determine if our design is viable. As the load on a battery increases, the voltage measured at the terminals decreases due to internal battery resistance. The battery model illustrated in Figure 2 includes an ideal battery and a resistor representing the battery&#8217;s internal resistance. V<sub>n</sub> represents the battery&#8217;s nominal voltage, R<sub>i</sub> represents the battery&#8217;s internal resistance in ohms, and V<sub>t</sub> represents the voltage measured between the battery&#8217;s terminals. This model predicts that as the current draw from the battery increases, the voltage seen at the terminals will be lower than the nominal voltage; V<sub>t</sub> = V<sub>n</sub> &#8211; R<sub>i</sub>*i, where i is the current drawn from the battery measured in amperes.</p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2025/08/Thevenin-Model-of-Battery-and-Wire-768x540-1.png"><img loading="lazy" decoding="async" width="300" height="211" src="/wp-content/uploads/2025/08/Thevenin-Model-of-Battery-and-Wire-768x540-1-300x211.png" alt="" class="wp-image-1651" srcset="/wp-content/uploads/2025/08/Thevenin-Model-of-Battery-and-Wire-768x540-1-300x211.png 300w, /wp-content/uploads/2025/08/Thevenin-Model-of-Battery-and-Wire-768x540-1.png 768w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 3 illustrates the addition of wire resistance to the model of Figure 2.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Our battery bank consists of four batteries interconnected with cables. These cables add additional resistance, R<sub>w</sub>, to the system, as illustrated in Figure 3. Four of these models, each with a potentially different value for R<sub>w</sub>, connected in parallel represent our battery bank. </p>



<p class="wp-block-paragraph">Now let&#8217;s put some numbers to these models and see what we expect from our battery bank. <a href="https://lionenergy.com/">Lion Energy</a> reports that the internal resistance of their UT 1200 battery is 17.84 mΩ. Using a <a href="https://www.tek.com/en/products/keithley/source-measure-units/2400-graphical-series-sourcemeter">Keithly 2450</a> SourceMeter, we measured the resistance of each 4/0 cable we created. We crimped lugs to both ends of each cable and measured each cable&#8217;s resistance from the center hole of one lug to the center hole of the other. There are two 11&#8243; cables measuring at 0.10 mΩ for the red cable and 0.13 mΩ for the black cable. There are four 6.5&#8243; cables measuring at 0.08 mΩ for the two red cables and 0.10 mΩ for each of the two black cables. Figure 4 illustrates the simplified models of our four batteries using the Lion Energy reported battery internal resistance and the measured values of the 4/0 wires interconnecting our batteries.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2022/01/Thevenin-Battery-Bank-1.png"><img loading="lazy" decoding="async" width="300" height="197" src="/wp-content/uploads/2022/01/Thevenin-Battery-Bank-1-300x197.png" alt="" class="wp-image-1291" srcset="/wp-content/uploads/2022/01/Thevenin-Battery-Bank-1-300x197.png 300w, /wp-content/uploads/2022/01/Thevenin-Battery-Bank-1-1024x674.png 1024w, /wp-content/uploads/2022/01/Thevenin-Battery-Bank-1-768x505.png 768w, /wp-content/uploads/2022/01/Thevenin-Battery-Bank-1-1536x1010.png 1536w, /wp-content/uploads/2022/01/Thevenin-Battery-Bank-1-2048x1347.png 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 4 illustrates a model for each of our four batteries. Each battery has the same internal resistance, but the wiring making up the battery bank gives each battery a slightly different value for R<sub>w</sub>.</figcaption></figure>
</div>


<p class="wp-block-paragraph">After connecting the four models illustrated in Figure 4 in parallel, circuit analysis and simplification results in the model shown in Figure 5. In this model, the resistance of the entire battery bank is 4.51 <meta charset="utf-8">mΩ, with the nominal voltage being 12.8 V. V<sub>bb</sub> represents the voltage seen across the two battery bank terminals that connect to the remainder of our power system. </p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2025/08/Final-Thevenin-Model-768x625-1.png"><img loading="lazy" decoding="async" width="300" height="244" src="/wp-content/uploads/2025/08/Final-Thevenin-Model-768x625-1-300x244.png" alt="" class="wp-image-1650" srcset="/wp-content/uploads/2025/08/Final-Thevenin-Model-768x625-1-300x244.png 300w, /wp-content/uploads/2025/08/Final-Thevenin-Model-768x625-1.png 768w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 5 illustrates our simplified battery bank model.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Note that the interconnect resistance is relatively small compared to the internal resistance of each battery. If the wiring resistance were zero, the model for the battery bank would be trivial to acquire. The battery voltage would have the value V<sub>n</sub>, and the series resistor would be the internal resistance of a single battery divided by the number of batteries. With an internal resistance of 17.84 <meta charset="utf-8">m<meta charset="utf-8">Ω, the ideal series resistor would have a value of 4.46 mΩ. Note that our model&#8217;s resistor has a value of 4.51 m<meta charset="utf-8">Ω, just a bit more than <meta charset="utf-8">the ideal. We could see currents approaching 275 A in our system. At 275 A, our model predicts that V<sub>bb</sub> would be 1.24 V lower than V<sub>n</sub>, or 11.56 V, while the ideal model predicts a Vbb of 11.57 V, not a significant difference. We expect typical maximum currents of 150 A. At this level, we expect V<sub>bb</sub> to be 0.68 V lower than V<sub>n</sub>, or 12.12 V.</p>



<h2 class="wp-block-heading" id="our-power-system">Our Power System</h2>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2022/01/12-V-Design-v4.png"><img loading="lazy" decoding="async" width="300" height="153" src="/wp-content/uploads/2022/01/12-V-Design-v4-300x153.png" alt="" class="wp-image-1267" srcset="/wp-content/uploads/2022/01/12-V-Design-v4-300x153.png 300w, /wp-content/uploads/2022/01/12-V-Design-v4-1024x523.png 1024w, /wp-content/uploads/2022/01/12-V-Design-v4-768x392.png 768w, /wp-content/uploads/2022/01/12-V-Design-v4-1536x785.png 1536w, /wp-content/uploads/2022/01/12-V-Design-v4-2048x1046.png 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 6 illustrates our entire power system.</figcaption></figure>
</div>


<p class="wp-block-paragraph">The power system we are endeavoring to build is described in a <a href="/rv-power-center-design/">previous post</a> and illustrated in Figure 6. The critical path in our system is the circuit from the battery bank to the inverter/charger and back. The other system components are essential but generate or consume far less power than the inverter/charger, resulting in lower currents and associated voltage drops.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2022/02/Final-Critical-Path-Schematic-1.png"><img loading="lazy" decoding="async" width="300" height="209" src="/wp-content/uploads/2022/02/Final-Critical-Path-Schematic-1-300x209.png" alt="" class="wp-image-1336" srcset="/wp-content/uploads/2022/02/Final-Critical-Path-Schematic-1-300x209.png 300w, /wp-content/uploads/2022/02/Final-Critical-Path-Schematic-1-1024x714.png 1024w, /wp-content/uploads/2022/02/Final-Critical-Path-Schematic-1-768x535.png 768w, /wp-content/uploads/2022/02/Final-Critical-Path-Schematic-1-1536x1071.png 1536w, /wp-content/uploads/2022/02/Final-Critical-Path-Schematic-1.png 1677w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 7 illustrates the components and cables that make up our system&#8217;s critical path and associated resistance values.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Figure 7 illustrates a simplified schematic of our system, including only the components and 4/0 cables involved in the high current critical path. These 4/0 cables should be capable of carrying 400 A of current. The figure also includes the resistance of each cable and components such as the 400 A class T fuse, battery disconnect switch, shunt, 400 A mega fuse, and the Lynx Distributor busbar system. The cable resistances were measured using the method previously described. Component resistances were obtained by properly torquing a cable of known resistance to each component connection, measuring the resistance from the end of one cable to the end of the other cable, and subtracting the resistance values of the two cables. </p>



<p class="wp-block-paragraph">In this simplified schematic, we have replaced the battery bank with an image of a single battery with the voltage and resistance values computed using our battery bank model. All resistance values are included in Table 1.</p>



<table style="width:100%; border-collapse: collapse; text-align: left; color: white;">
	<thead style="background-color: #293d47;">
		<tr>
			<th style="padding: 8px; border: 1px solid #ccc;">Component</th>
			<th style="padding: 8px; border: 1px solid #ccc;">mΩ</th>
		</tr>
	</thead>
	<tbody>
		<tr style="background-color: #798d97;">
			<td style="padding: 8px; border: 1px solid #ccc;">13&#8243; 4/0 red cable with lugs crimped to each end. Connects battery bank to fuse holder.</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.10</td>
		</tr>
		<tr style="background-color: #596d77;">
			<td style="padding: 8px; border: 1px solid #ccc;">400 A Class T <a href="https://www.amazon.com/gp/product/B0015357RW/ref=ppx_yo_dt_b_search_asin_title?ie=UTF8&#038;psc=1">fuse</a> and <a href="https://www.bluesea.com/products/5502/Class_T_Fuse_Block_with_Insulating_Cover_-_225_to_400A">holder</a>.</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.15</td>
		</tr>
		<tr style="background-color: #798d97;">
			<td style="padding: 8px; border: 1px solid #ccc;">38&#8243; 4/0 red cable with lugs crimped to each end. Connects fuse holder to battery disconnect switch.</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.22</td>
		</tr>
		<tr style="background-color: #596d77;">
			<td style="padding: 8px; border: 1px solid #ccc;"><a href="https://www.bluesea.com/products/6006/m-Series_Mini_On-Off_Battery_Switch_with__Knob_-_Red" rel="noopener" target="_blank">Blue Sea 300 A battery disconnect switch</a></td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.34</td>
		</tr>
		<tr style="background-color: #798d97;">
			<td style="padding: 8px; border: 1px solid #ccc;"><a href="https://shop.explorist.life/shop/all-products/connectors/victron-lynx-adapter/" rel="noopener" target="_blank">Copper bar connecting battery disconnect switch to Lynx Distributor.</a></td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.01</td>
		</tr>
		<tr style="background-color: #596d77;">
			<td style="padding: 8px; border: 1px solid #ccc;"><a href="https://www.victronenergy.com/dc-distribution-systems/lynx-distributor" rel="noopener" target="_blank">Victron Lynx Distributor busbar from main connection to first tap.</a></td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.02</td>
		</tr>
		<tr style="background-color: #798d97;">
			<td style="padding: 8px; border: 1px solid #ccc;"><a href="https://www.amazon.com/gp/product/B06VWHBFG1/ref=ppx_yo_dt_b_asin_title_o06_s00?ie=UTF8&#038;psc=1" rel="noopener" target="_blank">400 A Mega fuse bolted down within Lynx Distributor.</a></td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.11</td>
		</tr>
		<tr style="background-color: #596d77;">
			<td style="padding: 8px; border: 1px solid #ccc;">20&#8243; 4/0 red cable with lugs crimped to each end. Connects Lynx Distributor to inverter/charger.</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.13</td>
		</tr>
		<tr style="background-color: #798d97;">
			<td style="padding: 8px; border: 1px solid #ccc;">20&#8243; 4/0 black cable with lugs crimped to each end. Connects inverter/charger to Lynx Distributor.</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.19</td>
		</tr>
		<tr style="background-color: #596d77;">
			<td style="padding: 8px; border: 1px solid #ccc;">Victron Lynx Distributor busbar from first tap to main connection.</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.02</td>
		</tr>
		<tr style="background-color: #798d97;">
			<td style="padding: 8px; border: 1px solid #ccc;">Copper bar connecting Lynx Distributor to SmartShunt.</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.01</td>
		</tr>
		<tr style="background-color: #596d77;">
			<td style="padding: 8px; border: 1px solid #ccc;"><a href="https://www.victronenergy.com/battery-monitors/smart-battery-shunt" rel="noopener" target="_blank">Victron SmartShunt</a></td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.12</td>
		</tr>
		<tr style="background-color: #798d97;">
			<td style="padding: 8px; border: 1px solid #ccc;">58&#8243; 4/0 black cable with lugs crimped to each end. Connects SmartShunt to battery bank.</td>
			<td style="padding: 8px; border: 1px solid #ccc;">0.35</td>
		</tr>
		<tr style="background-color: #596d77;">
			<td style="padding: 8px; border: 1px solid #ccc;">Total circuit resistance from battery bank</td>
			<td style="padding: 8px; border: 1px solid #ccc;">1.77</td>
		</tr>
	</tbody>
</table>




<p class="wp-block-paragraph">While not critical to this work, it is interesting to note that according to <a href="https://www.engineeringtoolbox.com/copper-wire-d_1429.html">this table</a>, a 1000&#8242; segment of room temperature 4/0 copper wire has a resistance of 50 mΩ. This implies that our 13&#8243; cable connecting our battery bank to the rest of our system should have a resistance of 0.054 mΩ, yet it measures in at 0.10 mΩ. The crimped lugs contribute the difference of 0.046 mΩ. This implies that each 4/0 crimped lug contributes 0.023 mΩ of resistance. Another interesting fact is that our black 4/0 wires used in our battery bank wiring have a slightly higher resistance than their red equivalents. For example, the black 6.5&#8243; cables have a resistance of 0.10 mΩ while the equivalent red cables have a resistance of 0.08 mΩ.</p>



<p class="wp-block-paragraph">The total resistance of components and cables around our system&#8217;s critical path is 1.77 mΩ. With the inverter powering its maximum load of 3 kVA and just before system shutdown with a battery voltage of 11 V, the system currents would be approximately 273 A. Our system resistance at these high currents would result in a voltage drop of 0.48 V. However, no single system in our RV consumes this much power, and two or more of the large systems would exceed the maximum limit. We expect currents in the 150 A range when either our air conditioner or our microwave oven are operating. At 150 A, our voltage drop will be 0.27 V or 2%, a reasonable figure. Our system should be capable of providing just over 180 A while remaining at or below our 2.5% voltage drop goal.</p>



<h2 class="wp-block-heading" id="summary">Summary</h2>



<p class="wp-block-paragraph">Our goal is to create an RV power system that meets our <a href="/rv-electrical-upgrade/">design objectives</a>. One of our goals is to satisfy our power needs while suffering less than a 2.5% voltage drop due to system resistance. This goal will reduce the likelihood of excessive system ripple and other undesirable characteristics. Our system has a critical path resistance of 1.77 mΩ and should supply up to 180 A while staying below a 2.5% voltage drop; this should meet our needs and validate our design&#8217;s viability. Next up is the remainder of the implementation.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RV Power Center: Insulation and Storage</title>
		<link>/rv-power-center-insulation-and-storage/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 21 Jan 2022 00:19:30 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[Trailer Projects]]></category>
		<category><![CDATA[Blackstone 240 RKSB]]></category>
		<category><![CDATA[MORryde Cargo Tray]]></category>
		<category><![CDATA[ORV]]></category>
		<category><![CDATA[Outdoor RV]]></category>
		<category><![CDATA[Pass-through Storage]]></category>
		<category><![CDATA[Storage Tray]]></category>
		<guid isPermaLink="false">https://kelly.flanagan.io/?p=1223</guid>

					<description><![CDATA[This post is the seventh of an ongoing series of articles documenting and describing our RV electrical upgrade. Our previous post in this series described the original shore power wiring and our improvements. In addition, we discussed a severe flaw that was difficult to find but eventually corrected. In this post, we describe non-power-related improvements&#8230;&#160;]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">This post is the seventh of an ongoing series of articles documenting and describing our RV electrical upgrade. Our <a href="/rv-power-center-wiring/">previous post</a> in this series described the original shore power wiring and our improvements. In addition, we discussed a severe flaw that was difficult to find but eventually corrected. In this post, we describe non-power-related improvements to the pass-through storage area. These improvements include thermal insulation and an acquired storage system.</p>



<h2 class="wp-block-heading">Thermal Insulation</h2>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2021/11/Passthrough-and-Under-bed-Storage.png"><img loading="lazy" decoding="async" width="300" height="127" src="/wp-content/uploads/2021/11/Passthrough-and-Under-bed-Storage-300x127.png" alt="" class="wp-image-1058" srcset="/wp-content/uploads/2021/11/Passthrough-and-Under-bed-Storage-300x127.png 300w, /wp-content/uploads/2021/11/Passthrough-and-Under-bed-Storage-1024x432.png 1024w, /wp-content/uploads/2021/11/Passthrough-and-Under-bed-Storage-768x324.png 768w, /wp-content/uploads/2021/11/Passthrough-and-Under-bed-Storage-1536x648.png 1536w, /wp-content/uploads/2021/11/Passthrough-and-Under-bed-Storage.png 1678w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 1 illustrates our pass-through storage area and shows how the ceiling and rear walls of this area are adjacent to the living areas of the trailer. The ceiling of the storage area is the bottom bed support.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Only thin materials separate the ceiling and rear wall of our pass-through storage area from the bedroom area of our trailer, as illustrated in Figure 1. These materials provide little thermal insulation between the near outdoor conditions of our storage area and our living quarters. During colder weather, the front and top of each nightstand and the sides and bottom of the upper portion of the bed get cold.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2022/01/Crawl-Space-Insulation-scaled-1.jpeg"><img loading="lazy" decoding="async" width="282" height="300" src="/wp-content/uploads/2022/01/Morris-Connectors-1-282x300.jpeg" alt="" class="wp-image-1214" srcset="/wp-content/uploads/2022/01/Morris-Connectors-1-282x300.jpeg 282w, /wp-content/uploads/2022/01/Morris-Connectors-1-962x1024.jpeg 962w, /wp-content/uploads/2022/01/Morris-Connectors-1-768x818.jpeg 768w, /wp-content/uploads/2022/01/Morris-Connectors-1-1442x1536.jpeg 1442w, /wp-content/uploads/2022/01/Morris-Connectors-1-1923x2048.jpeg 1923w" sizes="auto, (max-width: 282px) 100vw, 282px" /></a><figcaption class="wp-element-caption">Figure 2 illustrates the foam panels added to the rear wall and ceiling of the pass-through storage area.</figcaption></figure>
</div>


<p class="wp-block-paragraph"><a href="https://www.evansoutdooradventures.com/?p=12694">Jason Evans</a>&#8216; post inspired us to mitigate this issue by insulating our pass-through area. Jason reported using <a href="https://www.evansoutdooradventures.com/?p=12694">R 1.93 insulation panels</a>, while we chose to use <a href="https://www.homedepot.com/p/R-Tech-1-in-x-4-ft-x-8-ft-R-3-85-Insulating-Sheathing-320821/202532854">R 3.85 panels</a> that offer twice the insulation at, you guessed it, nearly twice the price. </p>



<p class="wp-block-paragraph">Our space required nearly two 4&#8242; by 8&#8242; sheets of material. First, we used a box cutter and straightedge to subdivide each panel. Then, we gently pushed each piece into position and caulked them to keep them from falling out of place. We thought this was particularly important for those loosely hanging from the storage area ceiling. Figure 2 illustrates the complete installation. We also used expanding foam to seal around the 120 V outlets and USB port outlets on each nightstand. These modifications should help keep the cold and heat out and reduce the noise of our soon-to-be-added inverter/charger.</p>



<h2 class="wp-block-heading">Sliding Storage Tray</h2>



<p class="wp-block-paragraph">When we built our power center, we inadvertently created a bit of a storage dilemma by adding the wall visible at the far end of the pass-through storage area in Figure 2. As a result, we eliminated easy access to the far end of the nearly 7&#8242; deep remaining storage space accessible only via the remaining hatch. This depth would make it very difficult to get items from the far end of the area.</p>



<p class="wp-block-paragraph">To facilitate retrieving items from this area, we have acquired a <a href="https://www.morryde.com/products/cargo-tray-ctg80/">MORryde CTG80-2672-2DW</a> 80% extension cargo tray, illustrated in Figure 3. This tray is 26&#8243; wide and 72&#8243; long, perfectly fitting our space. In addition, the tray walls are 4.3&#8243; tall, and the tray floor comes pre carpeted. The structure bolts to the bottom of our storage area, and the tray rides on heavy-duty roller bearings and can support 500 pounds of gear. Working on electrical wiring in that area is now simple. I pull out the cargo tray, lay on it with my tools, and pull myself in. </p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2022/01/Cargo-Tray-Extnded-scaled-1.jpeg"><img loading="lazy" decoding="async" width="300" height="225" src="/wp-content/uploads/2022/01/Cargo-Tray-at-an-Angle-scaled-2-300x225.jpeg" alt="" class="wp-image-1272" srcset="/wp-content/uploads/2022/01/Cargo-Tray-at-an-Angle-scaled-2-300x225.jpeg 300w, /wp-content/uploads/2022/01/Cargo-Tray-at-an-Angle-scaled-2-1024x768.jpeg 1024w, /wp-content/uploads/2022/01/Cargo-Tray-at-an-Angle-scaled-2-768x576.jpeg 768w, /wp-content/uploads/2022/01/Cargo-Tray-at-an-Angle-scaled-2-1536x1152.jpeg 1536w, /wp-content/uploads/2022/01/Cargo-Tray-at-an-Angle-scaled-2-2048x1536.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 3 illustrates the MORryde CTG80-2672-2DW fully extended.</figcaption></figure>
</div>


<p class="wp-block-paragraph"><a href="https://www.morryde.com/products/cargo-tray-ctg60/">MORryde offers 60% extension trays</a> that only move in one direction, and while they support heavier loads, they also cost a bit more than the 80% extension trays. The 80% MORryde extension trays are intended to slide in both directions, but we won&#8217;t use this feature in our application. With the tray extended to 80% of its length, as illustrated in Figure 3, little of the tray remains within the storage space, making the extraction of items simple. Less drawer would stay within the storage space in some installations, but we chose to set ours back from the door nearly 8 inches (see Figure 4).</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2022/01/Cargo-Tray-Straight-On-scaled-1.jpeg"><img loading="lazy" decoding="async" width="300" height="185" src="/wp-content/uploads/2022/01/Cargo-Tray-Extnded-scaled-1-300x185.jpeg" alt="" class="wp-image-1273" srcset="/wp-content/uploads/2022/01/Cargo-Tray-Extnded-scaled-1-300x185.jpeg 300w, /wp-content/uploads/2022/01/Cargo-Tray-Extnded-scaled-1-1024x632.jpeg 1024w, /wp-content/uploads/2022/01/Cargo-Tray-Extnded-scaled-1-768x474.jpeg 768w, /wp-content/uploads/2022/01/Cargo-Tray-Extnded-scaled-1-1536x947.jpeg 1536w, /wp-content/uploads/2022/01/Cargo-Tray-Extnded-scaled-1-2048x1263.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 4 illustrates the MORryde cargo tray locked into place.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Another nice feature of the MORryde cargo trays is that they lock into place when stowed away. It is a simple matter to lift the blue handle on the unit&#8217;s left while pulling the tray out. When you push the tray back in, it locks in place. Figure 4 also illustrates how we chose to mount our tray towards the rear of the RV to leave space for long items we don&#8217;t often access. We&#8217;ll also take advantage of the wall space to the left and right of the tray for hanging light and narrow items such as axes, hammers, jack handles, etc. While this is an unexpected additional cost to our power upgrade project, it will create a better storage experience. </p>



<h2 class="wp-block-heading">Summary</h2>



<p class="wp-block-paragraph">This one was the most obvious and straightforward of all the projects we&#8217;ve tackled thus far. We cut some foam to size, put it in place, caulked the seams, and installed a pre-constructed cargo tray. Frankly, it was refreshing to begin a project with few unknowns, with an obvious list of steps to accomplish, and resulting in an end product that will add value to our camping experience. </p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RV Power Center: Wiring</title>
		<link>/rv-power-center-wiring/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 05 Jan 2022 03:30:53 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[Trailer Projects]]></category>
		<category><![CDATA[240RKSB]]></category>
		<category><![CDATA[Blackstone]]></category>
		<category><![CDATA[Blackstone 240 RKSB]]></category>
		<category><![CDATA[GFCI]]></category>
		<category><![CDATA[ORV]]></category>
		<category><![CDATA[Outdoor RV]]></category>
		<category><![CDATA[RV Power]]></category>
		<guid isPermaLink="false">https://kelly.flanagan.io/?p=1203</guid>

					<description><![CDATA[This post is the sixth of an ongoing series of articles documenting and describing our RV electrical upgrade. Our previous post in this series described the Victron Energy Lynx Distributor and a minor modification we made to it to meet our needs better. This post describes the original shore power wiring and our improvements. In&#8230;&#160;]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">This post is the sixth of an ongoing series of articles documenting and describing our RV electrical upgrade. Our <a href="/rv-power-center-lynx-distributor-modification/">previous post</a> in this series described the Victron Energy Lynx Distributor and a minor modification we made to it to meet our needs better. This post describes the original shore power wiring and our improvements. In addition, we discuss a severe flaw that was difficult to find.</p>



<h2 class="wp-block-heading">Shore Power</h2>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2022/01/50-A-Connector-1.png"><img loading="lazy" decoding="async" width="228" height="300" src="/wp-content/uploads/2022/01/50-A-Connector-1-228x300.png" alt="" class="wp-image-1210" srcset="/wp-content/uploads/2022/01/50-A-Connector-1-228x300.png 228w, /wp-content/uploads/2022/01/50-A-Connector-1.png 612w" sizes="auto, (max-width: 228px) 100vw, 228px" /></a><figcaption class="wp-element-caption">Figure  1 illustrates a typical 50 A shore power connector.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Figure 1 illustrates a typical 50 A RV shore power connector. A power cord may connect this outlet to a shore power pedestal that provides 50 A AC power to run appliances such as air conditioners, microwaves, televisions, and power converters for charging batteries. In addition, a 50 A connector can be adapted to a 30 A or 15 A power source using appropriate <a href="https://www.camco.net/adapters-dogbones">converters or dogbones</a>. Alternatively, this connector may be connected to a generator when shore power is unavailable. </p>



<p class="wp-block-paragraph">The connector illustrated in Figure 1 connects to the RV circuit breaker panel via appropriate conductors inside the RV. For example, our Outdoor RV 240 RKSB has 6/3 Romex that connects the shore power outlet to the main breaker in the circuit breaker panel, as illustrated in Figure 2. </p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2022/01/Circuit-Breaker-Panel-scaled-2.jpeg"><img loading="lazy" decoding="async" width="288" height="300" src="/wp-content/uploads/2022/01/Circuit-Breaker-Panel-scaled-2-288x300.jpeg" alt="" class="wp-image-1212" srcset="/wp-content/uploads/2022/01/Circuit-Breaker-Panel-scaled-2-288x300.jpeg 288w, /wp-content/uploads/2022/01/Circuit-Breaker-Panel-scaled-2-984x1024.jpeg 984w, /wp-content/uploads/2022/01/Circuit-Breaker-Panel-scaled-2-768x799.jpeg 768w, /wp-content/uploads/2022/01/Circuit-Breaker-Panel-scaled-2-1476x1536.jpeg 1476w, /wp-content/uploads/2022/01/Circuit-Breaker-Panel-scaled-2-1968x2048.jpeg 1968w" sizes="auto, (max-width: 288px) 100vw, 288px" /></a><figcaption class="wp-element-caption">Figure 2 depicts a typical RV circuit breaker panel with a 50 A service.</figcaption></figure>
</div>


<p class="wp-block-paragraph">6/3 Romex has three 6 AWG conductors and one 10 AWG bare copper wire. The 6 AWG red and black wires are connected to the 50 A breaker. The white wire is the associated neutral wire connected to the neutral busbar. The bare copper wire is attached directly to the ground busbar.</p>



<p class="wp-block-paragraph">The left side of the circuit breaker panel distributes 120 V AC to various trailer components, including 120 V AC outlets, television, microwave, air conditioner, and the power converter located beneath the circuit breaker panel, as illustrated in Figure 2. The power converter converts 120 V AC into the appropriate DC voltages to charge our 12 V RV batteries.</p>



<p class="wp-block-paragraph">The right side of the circuit breaker panel acquires power from the 12 V RV batteries and distributes this through blade fuses to various RV components such as lights, pull-outs, pumps, USB ports, audio systems, etc. In addition, the power converter output connects to the batteries via this side of the panel for charging.</p>



<h2 class="wp-block-heading">Inverter/Charger Power</h2>



<p class="wp-block-paragraph">The ability to use all of our 120 V appliances without needing shore power or a generator is the primary objective of this project. Including an inverter/charger in our power center will accomplish this goal. The desired inverter charger will pass through shore or generator power when available and provide 120 V power when they are not. The inverter/charger requires shore power as an input, and its 120 V AC output must be connected to the circuit breaker panel to enable this feature.</p>



<p class="wp-block-paragraph">We desired to leave the shore power outlet in its original location, requiring us to run 6/3 Romex from the shore power connector to our new power center and another strand of 6/3 Romex from our power center to the circuit breaker panel. Rather than running these two strands to two different locations, we determined to run both from our power center to just behind the circuit breaker panel.</p>



<p class="wp-block-paragraph">Rather than fussing with the RV underlayment, routing the cables around tanks, and through the frame, we hired this out to <a href="https://www.stewsrv.com/">Stewart&#8217;s RV</a>, our local RV service center. We purchased <a href="https://www.homedepot.com/p/Southwire-125-ft-6-3-Black-Stranded-Romex-SIMpull-CU-NM-B-W-G-Wire-63950002/202316279">125 feet of cable</a> and delivered it to the service folks at Stewart&#8217;s, who did an excellent job in all but one aspect. We&#8217;ll address the one flaw in the next section.</p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2022/01/Morris-Connectors-1.jpeg"><img loading="lazy" decoding="async" width="282" height="300" src="/wp-content/uploads/2022/01/Morris-Connectors-1-282x300.jpeg" alt="" class="wp-image-1214" srcset="/wp-content/uploads/2022/01/Morris-Connectors-1-282x300.jpeg 282w, /wp-content/uploads/2022/01/Morris-Connectors-1-962x1024.jpeg 962w, /wp-content/uploads/2022/01/Morris-Connectors-1-768x818.jpeg 768w, /wp-content/uploads/2022/01/Morris-Connectors-1-1442x1536.jpeg 1442w, /wp-content/uploads/2022/01/Morris-Connectors-1-1923x2048.jpeg 1923w" sizes="auto, (max-width: 282px) 100vw, 282px" /></a><figcaption class="wp-element-caption">Figure 3 illustrates conductors of 6/3 Romex spliced using two-conductor Morris connectors.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Once the wiring was in place, we made the right connections. First, we detached the original shore power connection from the circuit breaker panel and spliced it to one of the new 6/3 Romex strands using four <a href="https://www.amazon.com/gp/product/B09FC4XDXD/ref=ppx_yo_dt_b_asin_title_o04_s00?ie=UTF8&amp;psc=1">two-conductor Morris connectors</a>. These connections are illustrated in Figure 3. Next, we combined the two strands of 6/3 Romex in our power center using four additional Morris connectors. Finally, we joined the remaining conductors to the circuit breaker panel. With these modifications, shore or generator power comes in through the shore power connection, over the original 6/3 wire, through a new strand of 6/3 Romex to our power center, back through the second strand of 6/3 Romex, arriving at the circuit breaker panel. The before and after connections are identical, but the path has increased by roughly 50 feet.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2021/11/IMG_1972-scaled-1.jpeg"><img loading="lazy" decoding="async" width="300" height="225" src="/wp-content/uploads/2021/11/IMG_1972-scaled-1-300x225.jpeg" alt="" class="wp-image-1145" srcset="/wp-content/uploads/2021/11/IMG_1972-scaled-1-300x225.jpeg 300w, /wp-content/uploads/2021/11/IMG_1972-scaled-1-1024x768.jpeg 1024w, /wp-content/uploads/2021/11/IMG_1972-scaled-1-768x576.jpeg 768w, /wp-content/uploads/2021/11/IMG_1972-scaled-1-1536x1152.jpeg 1536w, /wp-content/uploads/2021/11/IMG_1972-scaled-1-2048x1536.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a></figure>
</div>


<p class="wp-block-paragraph">The spliced 6/3 Romex cables in our power center will be separated when our inverter/charger is installed. The 6/3 cable coming from the shore power connector will be tied to the inverter/charger&#8217;s input. The remaining cable will be connected to the inverter/charger&#8217;s 120 V AC output.</p>



<h2 class="wp-block-heading">Testing, Debugging, Repairing</h2>



<p class="wp-block-paragraph">Before connecting shore or generator power to our RV, I tested for short circuits within the circuit breaker panel. Unfortunately, I found a low resistance short circuit between the ground and neutral busbar. As a sub-panel, this should not be the case. I looked for obvious wiring flaws but didn&#8217;t find any. I returned our trailer to the service center, reporting a short circuit between ground and neutral.</p>



<p class="wp-block-paragraph">They made a thorough inspection of their work and found no flaws. They did what I should have done after installing the wires and before wiring things together. They tested the continuity between each possible conductor pair of both strands and found no short circuits. I accepted their findings and began a tedious search for the truth. I completely rewired the circuit breaker panel and eventually convinced myself that perhaps it was a strange interaction with the power converter, etc.</p>



<p class="wp-block-paragraph">I determined to plug the trailer in and see what happens. I knew it wouldn&#8217;t be a disaster, but I wanted to see if it would work. Unfortunately, immediately after plugging in the trailer, the GFCI outlet tripped. After much more work, I determined to plug it into a non GFCI protected outlet, and the trailer worked great. I carefully measured the potential between the trailer frame and ground to ensure my safety; everything was fine, well, it seemed fine.</p>



<p class="wp-block-paragraph">GFCI outlets trip because the current on the hot wires differs from that of the neutral wire by more than 5 mA. In other words, GFCI trips when current is flowing through some undesirable path, like through you. So why was this happening? A considerable amount of literature describes GFCI failures due to long runs, over 100 feet, for example. Essentially, the longer the wire, the more leakage between conductors, and when this exceeds 5 mA, the GFCI trips. Therefore, the longer the wire, the more likely this is. While I had successfully used the failing shore power connection previously, I also recognized that I recently added nearly 50&#8242; to the circuit through my new wiring. Perhaps this was the culprit. I moved the trailer much closer to the outlet and removed more than 50&#8242; of cords, and it still failed.</p>



<p class="wp-block-paragraph">After disconnecting the cable from the circuit breaker panel and removing the Morris connectors, I rechecked each conductor to ensure independence. Still no short circuits detected. Finally, in a last-ditch effort to find the flaw, I checked each wire in each cable for connectivity to the trailer&#8217;s frame. I found the elusive, obvious, and now embarrassing culprit. When the service center installed one of the new cables, its neutral wire was inadvertently electrically connected to the trailer&#8217;s frame.</p>



<p class="wp-block-paragraph">The circuit fails as follows. The ground busbar in the circuit breaker panel is appropriately attached to the trailer&#8217;s frame. However, when the faulty neutral wire is connected to the neutral busbar, the trailer&#8217;s frame connects the neutral and ground busbars, which is inappropriate for a subpanel.</p>



<p class="wp-block-paragraph">The test for this condition is simple and easily recreated. I returned the trailer to <a href="https://www.stewsrv.com/">Stewart&#8217;s RV</a>, demonstrated the test described above to them, and they accepted responsibility for the issue. They removed each cable clamp assembly installed, inspected for damage, and repaired where the wire insulation was cut and shorted the neutral wire to the frame. They demonstrated great integrity and excellent service through this ordeal and were consistently friendly and polite. They will get all of my future business.</p>



<h2 class="wp-block-heading">Summary</h2>



<p class="wp-block-paragraph">Our new AC wiring is in place and works perfectly. One of our goals was to end each sub-project with our trailer in order and available for camping. With this project done and working, we&#8217;ve reached that goal. Several takeaways:</p>



<ul class="wp-block-list">
<li> Morris connectors are amazingly awesome and much easier to work with than junction boxes.</li>



<li>Vendors, such as <a href="https://www.stewsrv.com/">Stwart&#8217;s RV</a>, with integrity are a pleasure to work with even when things seem tough.</li>



<li>Most importantly, <strong>check continuity between each conductor and between each conductor and the trailer&#8217;s frame!</strong> This one simple test would have saved dozens of hours of searching, poking, disconnecting, etc.</li>
</ul>



<p class="wp-block-paragraph">This project was our least understood because of the difficulty and uncertainty of physically dragging cable from the very front to the very back of our RV. However, the rest should be easy with this step done and working. Did I say that out loud?</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RV Power Center: Lynx Distributor Modification</title>
		<link>/rv-power-center-lynx-distributor-modification/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 27 Nov 2021 02:58:02 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[Trailer Projects]]></category>
		<category><![CDATA[Electrical Upgrade]]></category>
		<category><![CDATA[Lynx]]></category>
		<category><![CDATA[Lynx Distributor]]></category>
		<category><![CDATA[Power Center]]></category>
		<category><![CDATA[RV]]></category>
		<category><![CDATA[Victron]]></category>
		<guid isPermaLink="false">https://kelly.flanagan.io/?p=1190</guid>

					<description><![CDATA[This post is the fifth of an ongoing series of articles documenting and describing our RV electrical upgrade. Our previous post in this series described creating the physical space for our power center, initial wiring, and solar upgrades. In this post, we describe the Victron Energy Lynx Distributor and a minor modification we made to&#8230;&#160;]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">This post is the fifth of an ongoing series of articles documenting and describing our RV electrical upgrade. Our <a href="/rv-power-center-physical-space-wiring-and-solar-upgrade/">previous post</a> in this series described creating the physical space for our power center, initial wiring, and solar upgrades. In this post, we describe the Victron Energy Lynx Distributor and a minor modification we made to it to meet our needs better.</p>



<h2 class="wp-block-heading">Victron Lynx Distributor</h2>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2022/01/12-V-Design-v4.png"><img loading="lazy" decoding="async" width="300" height="153" src="/wp-content/uploads/2022/01/12-V-Design-v4-300x153.png" alt="" class="wp-image-1267" srcset="/wp-content/uploads/2022/01/12-V-Design-v4-300x153.png 300w, /wp-content/uploads/2022/01/12-V-Design-v4-1024x523.png 1024w, /wp-content/uploads/2022/01/12-V-Design-v4-768x392.png 768w, /wp-content/uploads/2022/01/12-V-Design-v4-1536x785.png 1536w, /wp-content/uploads/2022/01/12-V-Design-v4-2048x1046.png 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 1 illustrates the schematic of our proposed system with a 12 V battery bank.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Figure 1 illustrates the schematic of our power center design using a 12 V battery bank. Our 24 V design is very similar, and the differences are irrelevant to our present discussion regarding the Lynx Distributor shown in the lower center of the figure.</p>



<p class="wp-block-paragraph">Victron describes the Lynx Distributor as &#8220;A modular DC busbar, with locations for four DC fuses. It will monitor the status of each fuse, and indicate its condition with a LED on the front&#8221;. The Lynx Distributor is one of four Victron components for power distribution:</p>



<ul class="wp-block-list">
<li>Lynx Smart BMS</li>



<li>Lynx Distributor</li>



<li>Lynx Shunt VE.Can</li>



<li>Lynx Power In</li>
</ul>



<p class="wp-block-paragraph">See <a href="https://www.victronenergy.com/dc-distribution-systems">Victron Energy&#8217;s website</a> for a complete description of each component with associated datasheets, manuals, certification, etc.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2021/11/IMG_1994-scaled-2.jpeg"><img loading="lazy" decoding="async" width="300" height="157" src="/wp-content/uploads/2021/11/IMG_1994-scaled-2-300x157.jpeg" alt="" class="wp-image-1178" srcset="/wp-content/uploads/2021/11/IMG_1994-scaled-2-300x157.jpeg 300w, /wp-content/uploads/2021/11/IMG_1994-scaled-2-1024x537.jpeg 1024w, /wp-content/uploads/2021/11/IMG_1994-scaled-2-768x403.jpeg 768w, /wp-content/uploads/2021/11/IMG_1994-scaled-2-1536x806.jpeg 1536w, /wp-content/uploads/2021/11/IMG_1994-scaled-2-2048x1074.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 2 illustrates the internals of a Lynx Distributor comprising a positive and negative 1000 A busbar, four Mega fuse holders, and some electronics that indicate fuse status. </figcaption></figure>
</div>


<p class="wp-block-paragraph">We&#8217;ve chosen to use a Lynx Distributor in place of a couple of independent busbars and fuse holders that would otherwise be required. These items are conveniently packaged in the Lynx Distributor, as shown in Figure 2. The cost of separate components is close to the price of the Lynx Distributor, but using the Lynx Distributor should result in a clean, professional-looking result.</p>



<p class="wp-block-paragraph">Our schematic diagram shows that the Lynx Distributor connects to the battery bank via the disconnect switch and SmartShunt. The Lynx Distributor then distributes power to our inverter/charger, our solar charge controller, and the RV 12 V systems or, in the case of our 24 V design, to a 24 V to 12 V DC to DC converter. Mega fuses, housed within the Lynx Distributor, will protect the wiring between the Lynx Distributor and each of the connected loads.</p>



<p class="wp-block-paragraph">The Lynx DIstributor can report fuse status via its front panel LEDs if it is connected to a Lynx Smart BMS or a Lynx Shunt VE.Can. We don&#8217;t have either of these devices planned for our system. The following section describes how we provided power to the Lynx Distributor circuit board to enable the fuse monitoring feature. </p>



<h2 class="wp-block-heading">Lynx Distributor Hack</h2>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2021/11/IMG_1995-1.jpeg"><img loading="lazy" decoding="async" width="300" height="255" src="/wp-content/uploads/2021/11/IMG_1995-1-300x255.jpeg" alt="" class="wp-image-1180" srcset="/wp-content/uploads/2021/11/IMG_1995-1-300x255.jpeg 300w, /wp-content/uploads/2021/11/IMG_1995-1-768x654.jpeg 768w, /wp-content/uploads/2021/11/IMG_1995-1.jpeg 1016w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a></figure>
</div>


<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=8h-E1lkYCKg&amp;t=502s">Nate Yarbrough</a> produced a great video describing this hack to enable the lights on the front of a Lynx Distributor without having a Lynx Smart BMS or a Lynx Shunt VE.Can in your system. Victron expects this feature to be enabled by connecting the Lynx Distributor to these other devices with the included cable terminated with RJ-11 jacks. However, the Victron manual for the Lynx Distributor indicates which two of the four lines in the RJ-11 terminated wire are needed to power the device. Victron indicates that the device needs 5 V on pin 1, the yellow wire, and ground on pin 4, the black wire. So the task at hand is to generate 5 V from our available source of either 12 V or 24 V and provide it via an RJ-11 connector.</p>



<p class="wp-block-paragraph">Fortunately, Victron supplies a cable terminated on both ends with an RJ-11 connector. We cut this cable roughly in half, stripped back the outer covering, cut off the two unneeded wires, and stripped the remaining yellow and black wire in preparation for their connection to a 5 V source. </p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2021/11/IMG_2003-scaled-1.jpeg"><img loading="lazy" decoding="async" width="300" height="234" src="/wp-content/uploads/2021/11/IMG_2003-scaled-1-300x234.jpeg" alt="" class="wp-image-1182" srcset="/wp-content/uploads/2021/11/IMG_2003-scaled-1-300x234.jpeg 300w, /wp-content/uploads/2021/11/IMG_2003-scaled-1-1024x800.jpeg 1024w, /wp-content/uploads/2021/11/IMG_2003-scaled-1-768x600.jpeg 768w, /wp-content/uploads/2021/11/IMG_2003-scaled-1-1536x1200.jpeg 1536w, /wp-content/uploads/2021/11/IMG_2003-scaled-1-2048x1600.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 3 illustrates the small wiring harness, including M8 lugs, an RJ-11 connector, and a 24 V to 5 V regulator.</figcaption></figure>
</div>


<p class="wp-block-paragraph">We chose to use a tiny 24 V to 5 V step-down regulator, available <a href="https://www.amazon.com/dp/B076P4C42B?psc=1&amp;ref=ppx_yo2_dt_b_product_details">here</a>. Four of these devices were approximately $12. They come with wires and connectors attached and covered with heat shrink tubing. It was a simple matter to connect the outputs of this device to the RJ-11 wires and the inputs to two M8 wire lugs, see Figure 3. We then inserted the RJ-11 plug into the Lynx DIstributor and bolted the wire lugs to the busbars where additional Lynx devices could be attached, see Figure 4.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2021/11/IMG_2007-scaled-2.jpeg"><img loading="lazy" decoding="async" width="208" height="300" src="/wp-content/uploads/2021/11/IMG_2007-scaled-2-208x300.jpeg" alt="" class="wp-image-1185" srcset="/wp-content/uploads/2021/11/IMG_2007-scaled-2-208x300.jpeg 208w, /wp-content/uploads/2021/11/IMG_2007-scaled-2-709x1024.jpeg 709w, /wp-content/uploads/2021/11/IMG_2007-scaled-2-768x1109.jpeg 768w, /wp-content/uploads/2021/11/IMG_2007-scaled-2-1064x1536.jpeg 1064w, /wp-content/uploads/2021/11/IMG_2007-scaled-2-1418x2048.jpeg 1418w, /wp-content/uploads/2021/11/IMG_2007-scaled-2.jpeg 1773w" sizes="auto, (max-width: 208px) 100vw, 208px" /></a></figure>
</div>


<p class="wp-block-paragraph">These devices were advertised as 24 V ready, but we wanted to ensure they would handle the voltages in our eventual system. We tested them briefly by applying a voltage source to the Lynx Distributor busbars ranging from approximately 6 V to 30 V. The LEDs continued to function over this entire range. We don&#8217;t expect our Lynx Distributor to see voltages outside of this range. If your design operates at 36 V or 48 V, you will need to find an alternative voltage regulator.</p>



<p class="wp-block-paragraph">Many techniques, devices, and components could be used to accomplish this modification. However, our approach was straightforward. For convenience, we have included a list of the items that we used:</p>



<ul class="wp-block-list">
<li><a href="https://www.amazon.com/dp/B07FML8JHG?psc=1&amp;ref=ppx_yo2_dt_b_product_details">Victron Lynx Distributor</a></li>



<li><a href="https://www.amazon.com/dp/B076P4C42B?psc=1&amp;ref=ppx_yo2_dt_b_product_details">Voltage Converter</a></li>



<li><a href="https://www.amazon.com/dp/B07GDDKJ1D?ref=ppx_yo2_dt_b_product_details&amp;th=1">Wire Connectors</a></li>



<li><a href="https://www.amazon.com/dp/B087QTK1Y2?psc=1&amp;ref=ppx_yo2_dt_b_product_details">Wire Lugs</a></li>
</ul>



<h2 class="wp-block-heading">Summary</h2>



<p class="wp-block-paragraph">We will use the Victron Lynx Distributor in our power center to yield the functionality of two 1000 A busbars and four Mega fuse holders in an attractive and safe form factor. We discussed a modification to the Lynx Distributor so we can take advantage of the fuse monitoring capability. Finally, we pointed out a few of the devices we used for this project that we have found helpful many times.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RV Power Center: Physical Space, Wiring, and Solar Upgrade</title>
		<link>/rv-power-center-physical-space-wiring-and-solar-upgrade/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 21 Nov 2021 02:29:15 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[Trailer Projects]]></category>
		<category><![CDATA[Electrical Upgrade]]></category>
		<category><![CDATA[Outdoor RV]]></category>
		<category><![CDATA[Solar Power]]></category>
		<category><![CDATA[Victron]]></category>
		<category><![CDATA[Wiring]]></category>
		<guid isPermaLink="false">https://kelly.flanagan.io/?p=1139</guid>

					<description><![CDATA[This post is the fourth of an ongoing series of articles documenting and describing our RV electrical upgrade. In our previous post, we described our battery bank design and discussed where we would place it. In this post, we describe creating the physical space for our power center, our initial wiring, and our solar upgrades.&#8230;&#160;]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">This post is the fourth of an ongoing series of articles documenting and describing our RV electrical upgrade. In our <a href="/battery-bank-space-rv-power-center/">previous post</a>, we described our battery bank design and discussed where we would place it. In this post, we describe creating the physical space for our power center, our initial wiring, and our solar upgrades.</p>



<h2 class="wp-block-heading">Power Center Space</h2>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2021/11/Power-Center-Left-View.png"><img loading="lazy" decoding="async" width="300" height="233" src="/wp-content/uploads/2021/11/Power-Center-Left-View-300x233.png" alt="" class="wp-image-1035" srcset="/wp-content/uploads/2021/11/Power-Center-Left-View-300x233.png 300w, /wp-content/uploads/2021/11/Power-Center-Left-View-1024x797.png 1024w, /wp-content/uploads/2021/11/Power-Center-Left-View-768x597.png 768w, /wp-content/uploads/2021/11/Power-Center-Left-View.png 1234w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 1, This is a 3D model of the pass-through storage space we intend to use to house our power center.</figcaption></figure>
</div>


<p class="wp-block-paragraph">To house our chosen electrical components, we need to build a space similar to what we <a href="/rv-power-center-design/">previously presented</a>. Our proposed power center is illustrated in Figure 1. Component placement will likely change as we deal with surprises and take advantage of opportunities. However, the basic structure seems sound, and the creation of this space will allow progress.</p>



<p class="wp-block-paragraph">Figure 2 illustrates the physical space we&#8217;re starting with and some essential tools, Dewalt impact drill and a Diet Coke. First, we constructed a <a href="https://www.homedepot.com/p/Swaner-Hardwood-3-4-in-x-4-ft-x-8-ft-C-3-Birch-Domestic-Plywood-165921/202085716">3/4&#8243; plywood</a> wall that stretches from the bottom to the top of this compartment and lies flush against the short wall near the top.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2021/11/IMG_1962-scaled-2.jpeg"><img loading="lazy" decoding="async" width="300" height="225" src="/wp-content/uploads/2021/11/IMG_1962-scaled-2-300x225.jpeg" alt="" class="wp-image-1133" srcset="/wp-content/uploads/2021/11/IMG_1962-scaled-2-300x225.jpeg 300w, /wp-content/uploads/2021/11/IMG_1962-scaled-2-1024x768.jpeg 1024w, /wp-content/uploads/2021/11/IMG_1962-scaled-2-768x576.jpeg 768w, /wp-content/uploads/2021/11/IMG_1962-scaled-2-1536x1152.jpeg 1536w, /wp-content/uploads/2021/11/IMG_1962-scaled-2-2048x1536.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 2, This is the space we&#8217;re using for our power center. In this picture, we have already run some wires that we&#8217;ll describe in the next section.</figcaption></figure>
</div>


<p class="wp-block-paragraph">This approach required a cleat, see Figure 3, attached to the floor to support the plywood wall. To determine the location of the cleat, we held a small piece of plywood against the upper wall and marked the bottom of the compartment with blue tape where it landed when square.</p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2021/11/IMG_1963-scaled-2.jpeg"><img loading="lazy" decoding="async" width="300" height="225" src="/wp-content/uploads/2021/11/IMG_1963-scaled-2-300x225.jpeg" alt="" class="wp-image-1135" srcset="/wp-content/uploads/2021/11/IMG_1963-scaled-2-300x225.jpeg 300w, /wp-content/uploads/2021/11/IMG_1963-scaled-2-1024x768.jpeg 1024w, /wp-content/uploads/2021/11/IMG_1963-scaled-2-768x576.jpeg 768w, /wp-content/uploads/2021/11/IMG_1963-scaled-2-1536x1152.jpeg 1536w, /wp-content/uploads/2021/11/IMG_1963-scaled-2-2048x1536.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 3, This figure illustrates the lower cleat to support the plywood wall.</figcaption></figure>
</div>


<p class="wp-block-paragraph">The cleat, made of 1-1/4&#8243; by 1-1/4&#8243; lumber, was built by drilling screw holes and countersinking them to allow some 1-1/4&#8243; screws to reach well within the 5/8&#8243; flooring. We also had to add a top cleat, made of the same material, on the right-hand side of this space. The upper cleat was attached to the rectangular aluminum framing using 1-1/4&#8243; self-drilling screws. Finally, before the plywood wall went up, we needed to run a few electrical wires and rescue the Diet Coke.</p>



<h2 class="wp-block-heading">Initial Wiring</h2>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2021/11/ORV-2016-240-RKSB-Floorplan.png"><img loading="lazy" decoding="async" width="300" height="142" src="/wp-content/uploads/2021/11/ORV-2016-240-RKSB-Floorplan-300x142.png" alt="" class="wp-image-1113" srcset="/wp-content/uploads/2021/11/ORV-2016-240-RKSB-Floorplan-300x142.png 300w, /wp-content/uploads/2021/11/ORV-2016-240-RKSB-Floorplan-1024x484.png 1024w, /wp-content/uploads/2021/11/ORV-2016-240-RKSB-Floorplan-768x363.png 768w, /wp-content/uploads/2021/11/ORV-2016-240-RKSB-Floorplan-1536x725.png 1536w, /wp-content/uploads/2021/11/ORV-2016-240-RKSB-Floorplan.png 1546w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 4, This is the layout of our RV, a 2016 ORV 240 RKSB.</figcaption></figure>
</div>


<p class="wp-block-paragraph">As mentioned in <a href="/battery-bank-space-rv-power-center/">a previous post</a>, our RV is a 2016 <a href="https://www.outdoorsrvmfg.com/">Outdoor RV</a> Blackstone 240 RKSB. The floor plan of this model is illustrated in Figure 4. Our new power center will be located in the left-hand side of the pass-through storage area in the upper right-hand corner of Figure 4. Our shore power outlet is located at the left rear of the trailer, while our circuit breaker panel is located just under the refrigerator in the lower left of the figure.</p>



<h3 class="wp-block-heading">120 Volt AC Wiring</h3>



<p class="wp-block-paragraph">The shore power electrical outlet is wired directly to the circuit breaker panel. However, in our design, the shore power connector must be wired to the inverter/charger, and then the inverter/charger is wired to the circuit breaker panel. We ran <a href="https://www.southwire.com/wire-cable/building-wire/romex-brand-simpull-type-nm-b-cable/p/BW7">Southwire 6/3 Romex</a> from the circuit breaker panel area to the power center to accommodate this need. This line will carry the 50 A shore power to the inverter/charger. We then ran a second piece of 6/3 Romex from the power center back to the circuit panel area. This wire will carry inverter/charger output to the circuit breaker panel to energize our appliances.</p>



<p class="wp-block-paragraph">Many discussions in RV forums berate Romex because it shouldn&#8217;t be used in high vibration environments like RVs and boats. However, Southwire Romex larger than 10 AWG uses stranded wire for three conductors and a solid ground wire. Therefore, we used Romex instead of running a PVC conduit and pulling eight strands of 6 AWG THHN wire through it.</p>



<p class="wp-block-paragraph">We intended to run this wire ourselves, but it was a task I was not looking forward to. However, our local RV center, where we purchased our trailer several years ago, was willing to run the Romex for a few hundred dollars. That was a deal we couldn&#8217;t pass up. They ran the wire neatly and securely and left extra wire coiled behind the circuit breaker panel and in our power center.</p>



<h3 class="wp-block-heading">Solar PV Wiring</h3>



<p class="wp-block-paragraph">The original solar setup on our trailer was a single 150 W panel on the roof. The installer fed the PV cables through the roof and into an upper cabinet in the bedroom. An inexpensive PWM solar charge controller was installed in that cabinet and then wired down through the trailer cap to the a-frame-mounted batteries. </p>



<p class="wp-block-paragraph">Soon after purchasing the trailer, we upgraded this setup by replacing the single 150 W panel with three 200 W panels and the PWM controller with an MPPT controller. This upgrade used the existing wiring, and the new controller remained in the bedroom closet. This work aims to improve all aspects of our solar setup and get the solar charge controller out of our cupboard.</p>



<p class="wp-block-paragraph">We ran new <a href="https://www.amazon.com/dp/B01D7VBKQG?ref=ppx_yo2_dt_b_product_details&amp;th=1">10 AWG PV cables</a> from the roof through the portal and into the trailer attic near the front of the trailer. Next, we routed the PV cables behind the trailer cap and into our power center. Unfortunately, we purchased 20&#8242; lines with MC4 connectors on each end. We intended to cut the connectors off of one end and fish the cable to its destination. However, we inadvertently cut off the wrong connectors and ended up having to install our own. We should have purchased cable and installed MC4 connectors after they were in place.</p>



<h3 class="wp-block-heading">Battery and House Wiring</h3>



<p class="wp-block-paragraph">Eventually, as described in our previous post, we will move our battery bank and will need to provide 12 V from our power center to the rest of our trailer. For now, the batteries remain on the a-frame and feed the rest of the trailer from there. Therefore, we need to tap into the existing 12 V and ground line so our new solar charge controller can charge the batteries. Our completed project will eliminate the lines to the batteries.</p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2021/11/IMG_1966-scaled-2.jpeg"><img loading="lazy" decoding="async" width="225" height="300" src="/wp-content/uploads/2021/11/IMG_1966-scaled-2-225x300.jpeg" alt="" class="wp-image-1137" srcset="/wp-content/uploads/2021/11/IMG_1966-scaled-2-225x300.jpeg 225w, /wp-content/uploads/2021/11/IMG_1966-scaled-2-768x1024.jpeg 768w, /wp-content/uploads/2021/11/IMG_1966-scaled-2-1152x1536.jpeg 1152w, /wp-content/uploads/2021/11/IMG_1966-scaled-2-1536x2048.jpeg 1536w, /wp-content/uploads/2021/11/IMG_1966-scaled-2.jpeg 1920w" sizes="auto, (max-width: 225px) 100vw, 225px" /></a><figcaption class="wp-element-caption">Figure 6, Power and ground distribution travel through this space from the battery bank to the trailer.</figcaption></figure>
</div>


<p class="wp-block-paragraph">On the underside of the subfloor near the a-frame of our trailer, we found several auto reset circuit breakers. The breaker illustrated in Figure 6 has a direct connection to the positive terminal of our batteries. The positive terminal of our batteries and the trailer emergency brake are attached to the shown stud. We attached a <a href="https://www.amazon.com/dp/B097C8MYKW?psc=1&amp;ref=ppx_yo2_dt_b_product_details">6 AWG THHN</a> wire with a lug to that terminal and fished the wire into our power center.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2021/11/IMG_1969-1.jpeg"><img loading="lazy" decoding="async" width="297" height="300" src="/wp-content/uploads/2021/11/IMG_1969-1-297x300.jpeg" alt="" class="wp-image-1139" srcset="/wp-content/uploads/2021/11/IMG_1969-1-297x300.jpeg 297w, /wp-content/uploads/2021/11/IMG_1969-1-1013x1024.jpeg 1013w, /wp-content/uploads/2021/11/IMG_1969-1-768x776.jpeg 768w, /wp-content/uploads/2021/11/IMG_1969-1-1520x1536.jpeg 1520w, /wp-content/uploads/2021/11/IMG_1969-1.jpeg 1978w" sizes="auto, (max-width: 297px) 100vw, 297px" /></a><figcaption class="wp-element-caption">Figure 7, We used a Morris connector to connect a ground wire from the existing ground to our power center.</figcaption></figure>
</div>


<p class="wp-block-paragraph">A ground wire also travels through this area from the negative terminal of our batteries and into the trailer. We obtained ground by cutting the ground wire that travels through this space and connected both ends and a new 6 AWG THHN wire with a <a href="https://www.amazon.com/dp/B005GDFUDI?psc=1&amp;ref=ppx_yo2_dt_b_product_details">3 position Morris connector</a>, illustrated in Figure 7. These connectors are amazing and easy to use. Finally, we fished the new ground wire into our power center.</p>



<p class="wp-block-paragraph">After the 120 V AC, solar PV, and 12 V DC wiring were complete, we installed the plywood walls. With this done, the power center is ready for the addition of components. The empty power center can be seen in Figure 8.</p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2021/11/IMG_1971-scaled-1.jpeg"><img loading="lazy" decoding="async" width="300" height="225" src="/wp-content/uploads/2021/11/IMG_1971-scaled-1-300x225.jpeg" alt="" class="wp-image-1140" srcset="/wp-content/uploads/2021/11/IMG_1971-scaled-1-300x225.jpeg 300w, /wp-content/uploads/2021/11/IMG_1971-scaled-1-1024x768.jpeg 1024w, /wp-content/uploads/2021/11/IMG_1971-scaled-1-768x576.jpeg 768w, /wp-content/uploads/2021/11/IMG_1971-scaled-1-1536x1152.jpeg 1536w, /wp-content/uploads/2021/11/IMG_1971-scaled-1-2048x1536.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 8, The empty power center is illustrated with 120 V AC, 12 V DC, and solar PV wiring in place.</figcaption></figure>
</div>


<h2 class="wp-block-heading">Solar Additions</h2>



<p class="wp-block-paragraph">On the roof of our trailer, we installed a fourth <a href="https://www.amazon.com/dp/B0851RPM1Q?ref=ppx_yo2_dt_b_product_details&amp;th=1">200 W solar panel</a>, as illustrated in Figure 9. We couldn&#8217;t obtain another panel identical to the three we had, so we chose a panel with similar voltage characteristics and a current capability that slightly surpassed our existing panels. This panel will not constrain our system or be significantly limited by our existing panels; it should be a good match.</p>


<div class="wp-block-image is-resized">
<figure class="alignleft size-medium"><a href="/wp-content/uploads/2021/11/IMG_1978-scaled-2.jpeg"><img loading="lazy" decoding="async" width="300" height="244" src="/wp-content/uploads/2021/11/IMG_1978-scaled-2-300x244.jpeg" alt="" class="wp-image-1150" srcset="/wp-content/uploads/2021/11/IMG_1978-scaled-2-300x244.jpeg 300w, /wp-content/uploads/2021/11/IMG_1978-scaled-2-1024x833.jpeg 1024w, /wp-content/uploads/2021/11/IMG_1978-scaled-2-768x625.jpeg 768w, /wp-content/uploads/2021/11/IMG_1978-scaled-2-1536x1250.jpeg 1536w, /wp-content/uploads/2021/11/IMG_1978-scaled-2-2048x1666.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 9, A fourth 200 W solar panel was added to the roof and connected in series to the existing panels.</figcaption></figure>
</div>


<p class="wp-block-paragraph">Before celebrating the installation of our new panel or our wire routing prowess, we measured a voltage of 60 V across the PV cables. The addition of the fourth panel increased the PV voltage to approximately 80 V; success!</p>



<p class="wp-block-paragraph">We connected the PV cables to a <a href="https://www.amazon.com/dp/B0746DLP7S?ref=ppx_yo2_dt_b_product_details&amp;th=1">disconnect switch/circuit breaker</a> mounted in a <a href="https://www.amazon.com/dp/B07S75TV3V?ref=ppx_yo2_dt_b_product_details&amp;th=1">DIN breaker box</a> in our power center. Next, we used a couple of short lengths of PV cable to run from the breaker box to our <a href="https://www.victronenergy.com/solar-charge-controllers/smartsolar-250-85-250-100">Victron SmartSolar 150-45</a> solar charge controller. Finally, we connected our 12 V DC lines to the solar charger, and we&#8217;re back in business. Figure 10 illustrates the result.</p>


<div class="wp-block-image is-resized">
<figure class="alignright size-medium"><a href="/wp-content/uploads/2021/11/IMG_1977-scaled-2.jpeg"><img loading="lazy" decoding="async" width="300" height="225" src="/wp-content/uploads/2021/11/IMG_1977-scaled-2-300x225.jpeg" alt="" class="wp-image-1148" srcset="/wp-content/uploads/2021/11/IMG_1977-scaled-2-300x225.jpeg 300w, /wp-content/uploads/2021/11/IMG_1977-scaled-2-1024x768.jpeg 1024w, /wp-content/uploads/2021/11/IMG_1977-scaled-2-768x576.jpeg 768w, /wp-content/uploads/2021/11/IMG_1977-scaled-2-1536x1152.jpeg 1536w, /wp-content/uploads/2021/11/IMG_1977-scaled-2-2048x1536.jpeg 2048w" sizes="auto, (max-width: 300px) 100vw, 300px" /></a><figcaption class="wp-element-caption">Figure 10, The completed power center with solar charge controller and PV disconnect switch installed.</figcaption></figure>
</div>


<h2 class="wp-block-heading">The End Result</h2>



<p class="wp-block-paragraph">We&#8217;ve reached the end of another sub-project, and the trailer is once again ready to be used. We successfully created our power center space prepared to receive additional components. In addition, we routed all necessary power cables to this new space. Finally, we added a solar panel and upgraded our MPPT solar charge controller.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
